Copyright © 2013 Weidmüller Interface GmbH & Co. KG
74 / 103
All rights reserved. Reproduction without permission is prohibited.
192.168.21.254
255.255.255.0 (Class C)
NAT (masquerading) not set (leave checkbox empty)
Default gateway
172.16.1.254 (Router of the production network)
Only for Router 3
Operational mode:
IP Router
IP address parameters WAN Port:
static
10.1.1.254
255.255.0.0 (Class B)
NAT (masquerading) not set (leave checkbox empty)
IP address parameters LAN Port:
static
172.16.1.254
255.255.0.0 (Class B)
NAT (masquerading) not set (leave checkbox empty)
Default gateway
leave field empty (not necessary in this example)
► Click button “Apply settings” to activate the new settings.
Now the configured parameters will be
activated (but not saved)
. After a few seconds the web interface displays the
new IP addresses as shown in Figure 3. Please keep in mind that now the Router connection is lost due to changing the
IP address range of your connected WAN port.
Figure A4-3
: Display of activated new IP addresses of LAN and WAN port
5. Change the IP address of configuration PC
► To reconnect to the Router now change the IP address of the PC to an IP address of the new IP address
range 172.16.1.0/16
For re-connecting to Routers 1 and 2 chose e.g. IP address 172.16.1.100 and subnet mask 255.255.0.0. The input field
“Standard-Gateway” can be left empty.
Screenshot of Router 1 show-
ing changed IP addresses