8.
Reset to factory default settings by external push button
By pressing the push button "Factory Default" the security Router can be reset at any time and regardless of
the configuration to the default settings (factory settings).
How to set the factory settings:
1. Power off the Router
2. Press the button „Factory Default“ and keep it hold down
3. Power on the Router
and keeping button „Factory Default“ pressed while Router is booting
4. Release button „Factory Default“ when Power LED starts flashing fast (around 10 seconds after power on)
5. Wait until Power LED is glowing constantly green
Now the Router is ready to run with factory default settings.
Default factory settings of the Router:
Language:
Englisch user interface
Operation mode :
IP Router
IP address LAN port:
192.168.1.110 (static value)
Subnet mask:
255.255.255.0
NAT (Masquerading) on LAN port: Not activated
IP address WAN port:
192.168.2.110 (static value)
Subnet mask:
255.255.255.0
NAT (Masquerading) on WAN port: Not activated
Default gateway:
No entry
DNS:
DNS relay not activated
Firewall (Packet filter):
By default, data traffic in both directions between LAN and WAN is
allowed on both level Layer 2 and Layer 3. For that the packet filter
contains two default rules, called "Allow_L2" and "Allow_L3" (allow traffic
at Layer 2 and 3) which allows as "white lists" all network traffic.
IP routing
No static routes
Dynamic routing (OSPF, RIP) disabled
SNMP / DHCP / DNS
Disabled
VPN:
Disabled
Data prioritization
Disabled
Only model IE-SR-2GT-UMTS/3G