Copyright © 2013 Weidmüller Interface GmbH & Co. KG
49 / 103
All rights reserved. Reproduction without permission is prohibited.
Figure A1-2:
Default values of menu
IP configuration
► Configure the menu entries as following shown
Operational mode:
IP Router
IP address parameters
WAN
Port:
static
192.168.
20
.254
255.255.255.0 (Class C)
NAT (masquerading) not set (leave checkbox empty)
IP address parameters
LAN
Port:
static
192.168.
10
.254
255.255.255.0 (Class C)
NAT (masquerading) not set (leave checkbox empty)
Default gateway
Can be left blank because there exists no further target network
► Click button “Apply settings” to activate the new settings.
Now the configured parameters will be
activated (but not saved)
. After a few seconds the web interface displays the
new IP addresses as shown in Figure 3. Please keep in mind that you now have lost the Router connection due to
changing the IP address range of your connected LAN port.
Screenshot of the default IP
configuration of the Router