Figure 16: Configuration
Cut & Alarm
Tab
„Configuration“
In this menu it can be configured how the events "Cut" and "Alarm" - after they have occurred
– will be reset
(either manually by clicking on a button on the tab “State” or automatically after an elapsed time).
For more information please refer to Appendix C2 (Method 2).
Figure 17: Configuration
Cut & Alarm
Tab
„State“
Displays the current status of the events
"Internal Cut"
triggered eg by a special firewall rule
"External Cut"
Input of 24 VDC at 4-pin connector (at front side of the Router)
"Alarm"
triggered eg by a special firewall rule or by the function „Client monitoring“
By clicking on the buttons „Reset Cut signal“ and „Reset alarm signal“ you can manually reset the events
„Internal Cut“ and „Alarm“. The "External Cut" will automatically be reset if the 24 VDC at the 4-pin connector
will be removed.