Installation and Operating Manual
Page
20
Printed: 02/2015
3.1. Unloading / transport to location of installation
The unit is shipped as a fully assembled machine or in parts. For unloading, lift the unit by its
base profile or base frame.
-
Risk of serious injury or damage to property from dropping loads.
-
Observe the safety instructions of the transport equipment and lifting gear.
-
Do not stand under suspended loads.
When installing the unit in the plant, do not place it or any of its components at an angle or
upside down. Keep the fan parts in an upright position to prevent shearing damage to the
vibration dampers.
Correct installation of unit:
Never lift the unit by the heat exchanger connections, elastic pieces or other mounted
components.
Do not climb unto the unit. If this cannot be avoided, distribute your weight by using planks.
3.2. Unloading by forklift truck or lifting trolley
Ensure that the unit's base profile or frame is fully placed on the arms of the lift truck and that
the centre of gravity is located between the two fork arms.
When removing the truck forks, avoid damaging the profiles.