English
HMI
Run
LOC 1800rpm 00:00
1800
3.5
60.0
rpm
A
Hz
Run
LOC 1800rpm 00:00
2000
0
64.0s
Motor Speed Estimated Value
Run
LOC 1800rpm 00:00
0.0
rpm
0.0
A
0.0
V
00.0
Hz
00.0
V
00.0
%
0.0
kW
0
◦
C
00.0
%
Figure 4.4:
Default main screens
To access the menus, just press the ”Enter” key.
4.2 MENU ACCESS MODE - MENU LEVELS
When you press the ”Enter” key on a main screen, you access the menus. In the menus, it is possible to navigate
the groups and subgroups to access the variables.
Each variable has its own coding, containing its location in the menu structure and its identification. Digits are
separated by a period.
Example:
C2.1.4
= Motor rated voltage value
C2.1.4
= Configurations –> Motor –> Motor Data –> Rated Voltage
Level 1
Level 2
Level 3
Level 4
Edition
C
C2
C2.1
C2.1.4
Configurations
Motor
Motor Data
Rated Voltage
440V
4.2.1 Reading Variables - Status and Diagnostics Menus
All reading variables for the HMI are available in two main menus:
Status
and
Diagnostics
.
Status Menu:
It has reading variables with updated values: current, voltage and others.
Ready
LOC
0rpm 00:00
0.0
0.0
0
rpm
A
Hz
Ready
LOC
0rpm 00:00
Main Menu
Status
Diagnostics
Configurations
Assistants
Ready
LOC
0rpm 00:00
Status
1. Inverter
2. Measurements
3. I/Os
4. Functional Safety
5. Communications
Ready
LOC
0rpm 00:00
S2 Measurements
1. Motor Speed
2. Motor Torque
3. Inverter Output
4. Motor temperatures
5. Inverter temperatures
Ready
LOC
0rpm 00:00
S2.2 Motor Torque
1. Estimated Value
0.0%
Ready
LOC
0rpm 00:00
Motor Torque
S2.2.2 Estimated Value
0.0 %
Figure 4.5:
Average torque reading
Diagnostics Menu:
It has reading variables with values saved as a result of events: actuation of protections,
alarms, start and others.
CFW900 | 49