background image

wedi Fundo Riolito 

 wedi Fundo Shower System-Riolito

2

Overview & General Product Description of the wedi Fundo Shower Systems

The wedi Fundo Riolito Shower System offers full warranty coverage like all wedi Shower Systems, thanks to its its consistent and inherently waterproof core, and it’s range 
of specially engineered components. Fundo Riolito is internally waterproof due to its wedi XPS foam‘s closed cell structure, and naturally protects against mold or mildew like 
every wedi XPS foam based product. It is fast and clean to cut and fit custom designs while prefabrication reduces installation time significantly. The base features a strong 
and pre-sloped surface, allowing for tiling immediately whether you choose mosaic or large format tile. The wedi Fundo Riolito is designed with a 4-way slope which allows 
the base to maintain a level perimeter thickness despite its off-center drain location. This makes it safe and easy to install wedi Fundo Riolito in curbless shower designs and 
into a sufficiently recessed floor structure. Fundo Riolito can also be installed with a curb. Pre-sloped extension panels are available so that no limit exists for creating any size 
or shape for custom shower designs. Fundo Riolito is insulating, creating a thermal barrier that can prevent cold from transferring through the tiled surface, and make floor 
heating systems more efficient. It also has outstanding moisture and water exposure control compared to traditional mortar bed installations or other currently known methods 
for building showers, including the use of sheet or liquid waterproofing membranes which can be very thin and vulnerable, or they may offer water absorption into thin-set 
bonded seam areas. The wedi Fundo Riolito comes equipped with a wedi drain unit „Fundo Click and Seal™“, designed for safe performance and to ensure a perfect tiling 
experience. Key features of wedi’s Fundo Click and Seal™ drain are:

  

  A safe compression fit seal to the entire range of 2 in. floor waste pipes whether made of PVC, ABS, or Cast Iron. Special sealing gaskets are available for connections 

to Copper waste pipe.

  

 All drain parts function in a mechanical, simple and controlled process – with no glues or sealants needed

  

 “wedi Fundo Click and Seal™” mechanism for simple and safe assembly.

  

  wedi Fundo Click and Seal™ drain allows for a connection to a floor waste pipe that is easily cut flush with the floor, and it can connect safely even where the floor 

waste pipe is slightly angled (up to 5 Degrees). Please always test the seal of a drain to waste pipe connection. 

  

  wedi Fundo Riolito linear drain covers can be adjusted in height during tiling to meet all tile designs perfectly- from 1/4 in. tile to 1 in. tile. 

  

  Provided that the waste pipe and plumbing is open, wedi Fundo Riolito drain and drain cover flow rates exceed 14 gallons/minute.

These added values and perfection in details eliminate the technical concerns in shower installations. But this is not where wedi shower systems stop offering added value. 
The wedi Fundo shower system adds to your productivity and enables you to provide real value to your customers: Our wedi Fundo Shower systems reduce the installation 
time for just the shower floor from a 2 – 3 day process (includes drying times) to only 30 minutes when compared to traditional methods built with mortar beds and topical 
waterproofing. wedi helps you to turn showers into service quicker, cleaner, and safer. Especially for our contractors, Fundo Riolito helps to get to setting tile faster and on a 
much more consistent and tile friendly surface. Customers will appreciate the “no noise and no dirt and dust” installation. The wedi products do not contain harmful ingredients 
providing peace of mind to contractors and end users. The exact and consistently shaped slope fields support perfection in tile setting and design. The cement based resin 
surface coatings on our products provide a great bond surface for any tile, stone and many other materials. All good quality tile adhesives recommended for use in wet area 
applications, and made of cement – or epoxy based, work great on wedi Fundo Riolito. All this under one warranty for the entire shower from floor to wall.

EN

Содержание Fundo Riolito

Страница 1: ...uction Instrucciones de montaje Instructions d assemblage wedi Fundo Riolito Shower System with integrated linear drain Sistema de ducha con drenaje lineal integrado Syst me de douche avec coulement l...

Страница 2: ...pipes whether made of PVC ABS or Cast Iron Special sealing gaskets are available for connections to Copper waste pipe All drain parts function in a mechanical simple and controlled process with no gl...

Страница 3: ...ro fundido Se encuentran disponibles juntas de estanqueidad especiales para las conexiones con tuber as de desag e de cobre Todas las piezas de drenaje funcionan con un proceso mec nico sencillo y con...

Страница 4: ...rocessus m canique simple et contr l sans colle ni produit d tanch it Un m canisme wedi Fundo Click and Seal pour un assemblage simple et s r L coulement wedi Fundo Click and Seal permet le raccordeme...

Страница 5: ...substrates are dry and sufficiently loadbearing considering live and dead load Wood and Steel framing is sufficiently loadbearing plum and square Floor drain assembly below floor is stabilized fixed a...

Страница 6: ...y se cubre con sellador de juntas en un ancho de 1 pulg 25 4 mm en ambos lados de la uni n ES Disposer des cales de dimension nominale 50 8 mm 101 6 mm 2 po 4 po install es sur la plaque de base entr...

Страница 7: ...parfaitement aux bases des receveurs Naturellement les rampes et les panneaux d extension ne s adaptent pas non plus tous les mod les et doivent ventuellement aussi tre modifi s sur site EN Fundo Clic...

Страница 8: ...or extended wedi prefabricated extensions are pre notched They can be joined with other extensions in a mitered design joining two or more sides of a shower to be extended Make interlocking notch conn...

Страница 9: ...zar una sierra circular o un cuchillo multiuso afilado para cortar el canal nuevo a 1 2 pulg de ancho en el lado de la espuma azul que haya quedado descubierto Limpie el canal nuevo y la base y quite...

Страница 10: ...todas las paredes deben coincidir con las mediciones de distancia del centro del drenaje de la base Fundo a los bordes exteriores de su per metro incluido el canal Recorte un agujero de 5 pulg de di...

Страница 11: ...el canal perimetral de 1 2 pulg x 1 2 pulg en el cual la parte inferior del canal perimetral no debe ser m s gruesa que 1 4 pulg No corte cerca del drenaje integrado y mantenga una distancia m nima de...

Страница 12: ...ruction seuils rampes ou extensions wedi Nettoyer le receveur et les rainures et enlever toute la poussi re de scie l aide d un aspirateur ES EN 5 FR Apply the wedi provided safe lubricant to the blac...

Страница 13: ...su posici n de apoyo final Esto no requerir m s de un cuarto de vuelta Aseg rese de que exista una conexi n bien apretada tirando y empujando el cuerpo del drenaje y verificando que exista un asiento...

Страница 14: ...dified tile adhesive thinset ANSI 118 4 or better and comb through with a 1 4 in 1 4 in notched trowel Notches should be applied uniformly and point towards the shortest side of the base area You can...

Страница 15: ...le sur la face arri re du Fundo EN 11 EN ES FR Press the Fundo firmly into the thinset bed sloped side up ensuring that the installation is level along its perimeter and sides and thinset attachment a...

Страница 16: ...ubberized part of the Compression Spacer is not part of the wedi drain s waterproofing design it is used solely to keep all dirt out of the drain connections Con un cuchillo multiuso corte el separado...

Страница 17: ...res sion seal of the Drain Unit but remains in place later to serve as a hair catcher to protect the drain and make maintenance and cleaning easy Inserte la llave de la rejilla en la contratuerca en l...

Страница 18: ...nunca a menos de 6 pulg por encima de todos los accesorios de ducha Ins rer enti rement le panneau de construction wedi en le poussant dans la rainure du receveur de douche en s assurant que le cordon...

Страница 19: ...des cordons de joint de 12 7 mm 1 2 po entre toutes les conne xions de panneaux et les installer en les serrant bord bord L exc dent de joint doit tre tal l aide d un couteau mastiquer Tous les joint...

Страница 20: ...do not fit wedi standard collars so we can recommend optional best practices under wedi warranty Para que la instalaci n funcione correctamente es imprescindible impermea bilizar todos los puntos de i...

Страница 21: ...la Presione el sardinel que encaja a precisi n en el rea de conexi n Se pueden instalar bordillos delgados wedi utilizando completamente el sel lador de juntas wedi reemplaza a la fijaci n del mortero...

Страница 22: ...orts and how to adjust supports and drain covers for height to match the tile surface adjustment varies between models from 1 4 in low to 1 in high Ahora puede colocar la tapa de drenaje wedi Fundo Es...

Страница 23: ...should the water level exceed the height of the perimeter seams so that the fresh sealant may continue to a full cure without too much weight added during that process wedi recommends testing the dra...

Страница 24: ...no est n sujetas a la recomendaci n general que se ha descrito anteriormente en relaci n con los materiales ligantes en funci n de las dimensiones de la loseta Cuando se instalen losetas no cuadradas...

Страница 25: ...tensions ou les rampes l paisseur des carreaux ne doit g n ralement pas tre inf rieure 3 2 mm 1 8 po Choisir des mat riaux de pose appropri s pour le type de pierre de c ramique ou de carreaux de verr...

Страница 26: ...to Puede enlosarse con adhesivo o pegamento ep xicos o sellador de juntas wedi Puede usarse con losetas o piedras de 0 25 pulg 6 4 mm y 0 5 pulg 12 7 mm cubierta opu esta La tapa de drenaje puede ajus...

Страница 27: ...hannel covers please have a look at the installation instructions in the packaging Para instalar las cubiertas de canal lineal revise las instrucciones de instalaci n que contiene el embalaje Pour l i...

Страница 28: ...mejor saber y en pruebas independientes ICC PMG Report wedi se reserva el derecho de modificar la informaci n t cnica y las instrucciones Les informations et les instructions wedi sont bas es sur les...

Отзывы: