PARAMETERS SETTING: (1ST LEVEL)
S2
Press this button to scroll the list of settings to edit.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S2) to save the setting and quit the menu.
Tab. 3 - Parameters of the 1st level menu: MMA mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
-
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
10 A
10 A
500 A *5
Ho.S.
HOT-START
0 %
*SYn 100 % *1 *2
Ar.F.
ARC FORCE
0 %
*SYn 250 % *1 *3
Tab. 4 - Parameters of the 1st level menu: DESEAMING mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
-
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
10 A
10 A
500 A *5
Tab. 5 - Parameters of the 1st level menu: CONTINUOUS DC TIG mode
ACRONYM
PARAMETER MIN
DEFAULT MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C. STARTING
CURRENT
5 A 50
A 500
A *4 *8
2 %
50 % 200 % *4 *8
Sl.u.
SLOPE UP
0.0 s
0.0 s
25.0 s
-
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
5 A
80 A
500 A *5
S.Cu.
SECOND CURRENT B-LEVEL
10 % 50 % 200 % *1
Sl.d.
DOWN SLOPE
0.0 s
0.0 s
25.0 s *8
F.Cu. FINAL
CURRENT
5 A 5
A 500
A *4 *8
5 %
5 %
80 % *4 *8
Po.G.
POST GAS TIME
0.0 s 10.0 s 25.0 s
Tab. 6 - Parameters of the 1st level menu: PULSED TIG DC mode
ACRONYM
PARAMETER MIN
DEFAULT MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C. STARTING
CURRENT
5 A 50
A 500
A *4 *8
2 %
50 %
200 % *4 *8
Sl.u.
SLOPE UP
0.0 s
0.0 s
25.0 s
-
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
5 A
80 A
500 A *5
S.Cu.
SECOND CURRENT B-LEVEL
10 %
50 %
200 % *1
b.Cu. BASE
CURRENT
1 %
40 %
200 %
PE.t.
PEAK TIME
1 %
50 %
99 %
bA.t. BASE
CURRENT
0.1 s
5.0 s
5.0 s
P.Fr.
PULSED CURRENT FREQUENCY
0.1 Hz 100 Hz 2.5 kHz
Sl.d.
DOWN SLOPE
0.0 s
0.0 s
25.0 s *8
F.Cu. FINAL
CURRENT
5 A 5
A 500
A *4 *8
5 %
5 %
80 % *4 *8
Po.G.
POST GAS TIME
0.0 s
10.0 s
25.0 s
*1:
This parameter is set as a percentage referred to the value of the following parameter:
WELDING CURRENT
*2:
The value is limited to 250 A max.
*3:
The value is limited to 500 A max.
*4:
The value of this parameter can be set as a percentage of the welding current or as an absolute value expressed in Amperes.
*5:
This setting is used to adjust both parameters.
*SYN: This code indicates that parameters control is synergic.
The optimal value of this parameter is set automatically by the microprocessor on the basis of the preset welding current value.
When SYN is installed, to display the synergic value press the following button: S5
This value can be displayed but it is not user-adjustable.
*8:
The parameter is displayed but it is not used the during welding process when the following setting is present:
MULTI TACK = ON
Содержание Cruiser 402 T
Страница 37: ...Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH 37 50...
Страница 38: ...Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T 38 50...
Страница 39: ...Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH 39 50...
Страница 40: ...Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T 40 50...
Страница 42: ...Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T 42 50...
Страница 43: ...Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH 43 50...
Страница 44: ...Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T 44 50...
Страница 45: ...Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH 45 50...
Страница 49: ...Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH 49 50...
Страница 50: ...Cod 006 0001 1680 24 04 2014 v2 0 ENGLISH Cruiser 402 T Cruiser 502 T Power Pulse 402 T Power Pulse 502 T 50 50...