Chapter 6
Installation and initial startup
32708885 Geset 100
Version: 16.07.13
Page 34 of 77
GB
Connection to supply voltage
Safety instructions
Hazards from actively controlled movements.
RISK OF INJURY FROM PULLING AND CRUSHING!
Immediately after turning on, several system parts make a refe-
rence run or move to its home position!
- Maintain a distance from powered system components.
Fig. 6-1: 230V-CEE- Connection plug
Requirements
¥
Power supply according to "Specifications" on page 24 is installed close to or
(max. 1,5 m distant) from the labeling site.
¥
Main switch is in OFF/ 0-position
¥
Power cabling is available
Instruction
Please connect the labeling system with the power supply as follows.
Step
Procedure
1
Connect the power voltage cable with the power socket.
Risk of injury from pulling in and crushing!
Immediately after turning on, several system parts make a reference run or
move to its home position!
-
Maintain a distance from powered system components.
2
Turn on the main switch.
3
Turn on the machine and control the running directions of the drives. If the
drives run against the intended driving direction, turn off the system imme-
diately. The electrical rotating field must be changed in this case by an Elec-
trician.
4
Stop the labeling station and turn off the main switch.
Содержание Geset 100