Pump and Fluid Systems
Chapter 5: Assembly/Disassembly
weatherford.com
51
MP-16 2-Piece 5000 psi January 2013
Chapter 5: Assembly/Disassembly
5.1
L-Style Fluid End Maintenance Procedures
The following are the standard procedures for disassembling and reinstalling the L-Style
fluid end of the MP-16 pump.
CAUTION
Even while at rest, the fluid end of the system is under significant
pressure, which can cause significant equipment damage and injury to
nearby personnel if vented inappropriately. All pressure must be
properly vented from the system before any maintenance on the MP-16
is performed (see 4.5.1: Venting Pressure in the Fluid End).
5.1.1
Removing the Discharge Manifold
1
Remove the sections of the discharge piping
connected to the discharge manifold.
2
Remove the nuts connecting each of the
discharge modules to the discharge manifold.
WARNING
The discharge manifold is a
weighty piece of metal
which can cause serious
injury if dropped. Be sure
the manifold is sufficiently
supported before removing
the fasteners.