WCSEE- T300 INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Page 17 of 21
7.
PROBLEM SOLVING
Poor Effluent
Blower not running Refer to 7.2
No Air bubbles in
filter chamber
Refer to 7.3
Poor air distribution Refer to 7.6
Poor flow control
Refer to site
Blower not Running
Symptoms
Corrections
Power cut
If temporary (24/48 Hours) do nothing. If extended, obtain
alternative source of power or tanker sewage away.
Important: on power being returned to three phase supplies check
for correct rotation of blowers
Power supply fault
Switch off blowers check fuses and any RCD breakers, on 3-phase
supplies check for correct rotation. Switch blowers to on and the
blowers should start. If not switch off and call electrician.
Blower overload has
tripped
Check for any obvious causes, reset overload and switch to on.
Blowers should start, if not switch off and call an electrician.
Blower runs
intermittently
Check that the cooling fan is running and the air ducts are clear, as
overheating in the cabinet will cause the high temperature trip to
switch off the power to all but the fan and beacon if fitted. Replace
fan if it has failed. Temporary solutions if the weather is fine: leave
the kiosk door open but ensure that no one can gain access to
electrical or rotating mechanisms.
No air bubbles showing on the surface of the filter section
Symptom
Corrections
Blower not running
Refer to 7.2
Blower running
Check all valves are open in the kiosk and main unit. Check that the
airlines are not broken or leaking. Find where the air is escaping
from pipe work and repair. Check inlet filter(s).
Blockages
Symptom
Correction
Level in sections is
higher than normal
If the plant has been flooded due to high water level or other
cause the 'V' notches may have become blocked these should be
cleared of any debris the material should be returned to the
primary settlement tank.