background image

WCSEE- T300 INSTALLATION, OPERATION AND MAINTENANCE MANUAL  

 

Page 9 of 21                 

 

4.

 

Introduction 

The process used within the WCSEE SAF has been developed to meet the more 
stringent discharge consents now being imposed by the Environment Agency, 

particularly with reference to low ammonia levels.  The HiPAF can achieve 

ammonia standards better than 10mg/l.  
 

The T300 and T3HP (for Hire Use) has been designed for above ground 
installation only.  

The T300 is equipped with an optional access ladder and handrails, where as the 

T3HP does not require any top-level access. This is shown in more detail in the 
next pages.    

                                 
Blowers and controls to provide the air are housed in a separate standalone kiosk 

adjacent to the plant. The tank and kiosk are manufactured in GRP for corrosion 

resistance and long life. 

 

*As  these  units  are  above  ground  and  generally  receiving  pumped  flows,  it  is 
therefore necessary to provide suitable flow control before the effluent is received 

by the unit. 

 
The  plant  should  receive  Dry  Weather Flow

 

as  stated  in  the  relevant  quotation  or 

design documentation; ensuring adequate hydraulic retention time for the relevant 
biological processes to take place. 

 
 
WCSEE advises the following for lifting practices for the T300 & T3HP tanks:  

Checks: 

 

Inspect all lifting points and tension if required with a suitable tool. 

 

The unit must be hoisted empty of all material and fluids. 

Test lift the unit to check that the centre of gravity of the unit is in the correct 

location (See drawing supplied by WCSEE LTD), and that all of the chains are 

taut. It is critical to ensure a balanced lift, but if in doubt 

don’t lift the tank.

 

 
 
 
 

 
 
 
 

 

 

 

Содержание WCSEE T300

Страница 1: ...WCSEE T300 T3HP FOR HIRE INSTALLATION OPERATION MAINTENANCE MANUAL...

Страница 2: ...M E installation 6 Warranty limitations and exemptions 6 Chargeable non warranty work 6 3 Risk assessment 7 Introduction 7 3 1 1 Installation Design Considerations 7 3 1 2 Installation and positioning...

Страница 3: ...AIR DISTRIBUTION OVER THE FILTER SECTION 18 Blocked air Diffusers 18 Filter media partially blocked by excessive biomass 18 Filter media partially blocked with sludge 18 8 PLANT START UP 19 Introducti...

Страница 4: ...D T300 tanks have been laid out to ensure that health and safety on site is optimised in line with designer duties specified by the CDM regulations 2015 It will be safe manner and agrees with comments...

Страница 5: ...contact with sewage report to your doctor immediately advising them of the circumstances Vaccinations To avoid the possibility of illness it is recommended that all site personnel have the following v...

Страница 6: ...ranty are limited life of consumable components subject to normal wear and tear Chargeable non warranty work Service charges will be incurred including parts and labour due to the following Unauthoriz...

Страница 7: ...will be using it e g domestic light industrial etc Costs legal implications and siting in consideration to shared systems The whereabouts of wells boreholes and springs used as sources of potable wate...

Страница 8: ...until the system is complete commissioned and is operating in a stable manner 3 1 3 Maintenance The legal responsibility for the plant as far as operation and maintenance and on going discharge is co...

Страница 9: ...e tank and kiosk are manufactured in GRP for corrosion resistance and long life As these units are above ground and generally receiving pumped flows it is therefore necessary to provide suitable flow...

Страница 10: ...evel access 10m of 2 High temperature air hose is provided to connect the blower process air to the tank Connecting the air hose to the Kiosk 2 hosetail connection mounted on the manifold within the K...

Страница 11: ...rrangement and the unit comes equipped with a lid for access by WCSEE only 10m of 2 High air temperature hose is provided to connect the blower process air to the tank Connecting the air hose to the K...

Страница 12: ...on the water temperature and site conditions It is important that the sewage input conditions are kept within the plant design criteria Refer to section 8 Start Up Procedure Both the T300 Tank and the...

Страница 13: ...n the Auto position As indicated in Picture 1 below This set up will allow the timer to be in operation When the main switch located on the front of the control panel is in the Auto position the low a...

Страница 14: ...de will run the blower in manual setting as indicated in Picture 3 below It is advisable that once a week to run the blower s in manual mode for 4 hours to scour the media Picture 3 On the Timer selec...

Страница 15: ...st be installed by WCS EE or the process of the sewerage treatment plant will not be guaranteed by WCS EE On factory fitted timers a visit is required after 2 months in operation to check the D O Diss...

Страница 16: ...ower air filters are clear and knock off any collected dust or replace if necessary On the T3HP Hire Unit the air diffusers for the biozone are split into two zones In normal operation the air feeds b...

Страница 17: ...ot switch off and call an electrician Blower runs intermittently Check that the cooling fan is running and the air ducts are clear as overheating in the cabinet will cause the high temperature trip to...

Страница 18: ...on for the position of bubbles The increased pressure should clear any blockage in the diffuser If not the diffuser can be removed by switching the air supply blower off and disconnecting the diffuse...

Страница 19: ...en and this will be partially converted to nitrogen gas before being discharged The carbonaceous bacteria are more prolific and also less prone to damage by chemicals cleaning agents than the nitrifyi...

Страница 20: ...e poor with little treatment In order to reduce the time to full treatment the plant can be seeded with activated sludge and or proprietary bacteria BUT a quantity of normal sewage will also be requir...

Страница 21: ...inue running the blowers 4 During this time the biomass will gradually die off with the fresh water passing through the unit 5 Continue this operation for a minimum period of one 1 week to ensure all...

Страница 22: ......

Отзывы: