background image

CLICK 516 

 

USER GUIDE

Sensor HD and verifies that the duration field in the message is less than 1.9 seconds. If 

it is found to be longer than 1.9 seconds, the duration is changed to 1.9 seconds.
The event data message is converted to a contact closure message and passed onto a 

Click contact closure card using the Z4 protocol.

In normal state the Click 516 also polls Interval Data from a SmartSensor HD and 

checks the speed and occupancy for each lane. The speed and occupancy is tested to 

determine if the speed is below the speed threshold and the occupancy is above the 

occupancy threshold. If this condition is true, the Click 516 enters HIOCC state; if this 

condition is false, the Click 516 stays in NORMAL state.

The eight LEDs on the front of the Click 516 will indicate what state the first eight lanes 

are in. If the first LED is on Solid, the first lane is in the Normal state. If the first LED is 

flashing, the first lane is in the HIOCC state. This will only work for the first eight lanes. 

Note

There are only eight LEDs on the front of the Click 516. This means that only the first 
eight lanes will be monitored by the Click 516 front panel.

The LEDs will always come on (starting with the first LED corresponding to the lane 

closest to the SmartSensor) regardless of what the lane name is set to. If only two LEDs 

are on, then the sensor is only configured for two lanes.

 

˽

HIOCC State –

 In HIOCC state, the Click 516 polls event data messages from a Smart-

Sensor HD and verifies that the duration field in the message is greater than 2.3 sec-

onds. If it is found to be shorter than 2.3 seconds the duration is changed to 2.3 seconds.
The event data message is converted to a contact closure message and passed onto a 

Click contact closure card using the Z4 protocol.

In HIOCC state the Click 516 also polls interval data from a SmartSensor HD and 

checks the speed for each lane. The speed is tested to determine if the speed is above 

the speed threshold. If this condition is true, the Click 516 enters NORMAL state; if 

this condition is false, the Click 516 stays in HIOCC state.

Note

It takes speed and occupancy to enter HIOCC state. It only takes speed to exit the 
mode and return to the NORMAL state.

Содержание Click 516

Страница 1: ...Click 516 USER GUIDE...

Страница 2: ...www wavetronix com 78 East 1700 South Provo Utah 84606 801 734 7200 Click 516 USER GUIDE...

Страница 3: ...CC rules which state that operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interf...

Страница 4: ...ent data messages and interval data from a SmartSensor HD Figure 1 The Click 516 The Click 516 operates in the following two states Normal and HIOCC These states are described below Normal State In no...

Страница 5: ...te There are only eight LEDs on the front of the Click 516 This means that only the first eight lanes will be monitored by the Click 516 front panel The LEDs will always come on starting with the firs...

Страница 6: ...hicle speed data to change the duration to greater than 1 9 seconds Once the Click 516 receives an interval where the speed is greater than the threshold the Click 516 will go out of HIOCC mode and al...

Страница 7: ...ule is used to forward data retrieved from the sensor and it is also used to configure the device with Click Supervisor The DB 9 port on the front of the Click 516 is the only port that is active when...

Страница 8: ...operation all DIP switches should be in the OFF position Warning The sixth switch of DIP switch 1 controls the mode of the device Make sure that this switch is in the OFF position If it gets turned o...

Страница 9: ...Click 516 Located on the front of the module below the DB 9 connector is a push button labeled Mode Switch The push button allows you to make selections from the menu see the Op erating Modes section...

Страница 10: ...complete properly Operating Modes The Click 516 has two operating modes Run mode and Device Setup mode These modes are accessed through the mode menu which is controlled via the push button the system...

Страница 11: ...ion The mode will now start running Run Mode blue solid Run mode is the first mode presented in the mode selection process but usually the second one to be used It might first be necessary at least th...

Страница 12: ...a SmartSensor HD and veri fies that the duration field of in the message is greater than 2 3 seconds If it is found to be shorter than 2 3 seconds the duration is change to be 2 3 seconds The Event D...

Страница 13: ...Click Supervisor using the Communication task from the main menu When detected the Click 516 will show up in the device list Highlight the device and press Select and after transferring the necessary...

Страница 14: ...elect the Setup Click task from the main menu and this will give the list of available drivers Select the Expert driver and click OK Figure 6 List of Drivers The driver will load the appropriate infor...

Страница 15: ...e Occupancy threshold that is used along with the Min Speed to determine if the Click 516 should enter HIOCC MODE The Speed of the interval must be below the Min Speed and the Occupancy of the interva...

Страница 16: ...sensor is storing Interval Data This field is read only Time Zone Allows you to select the appropriate time zone Table 3 Description of Sensor Tab Note If any of the read only fields are blank it mea...

Страница 17: ...t LED Solid Reset all settings except Serial Number and XML variable map Second LED Solid Reset all settings except Serial Number After being reset the Click 516 will return to the last mode that it w...

Страница 18: ...Euro Pat Nos 1435036 1438702 1611458 Other US and international patents pending Wavetronix SmartSensor Click Command and all associated logos are trademarks of Wavetronix LLC All other product or bra...

Страница 19: ...www wavetronix com...

Отзывы: