CLICK 516 

•  USER GUIDE 

5

Note

All the tests are performed on Interval Data, not Per Vehicle data.

Note

In the UK, if a vehicle occupies a loop for more than 1.9 seconds the MIDAS controller 
sends a signal indicating that the lane has entered a HIOCC state. Due to the more 
robust nature of the SmartSensor HD, the Click 516 will monitor the interval data and 
when the speed is below a threshold and the occupancy is above a threshold the Click 
516 will modify all incoming pre-vehicle speed data to change the duration to greater 
than 1.9 seconds. Once the Click 516 receives an interval where the speed is greater 
than the threshold the Click 516 will go out of HIOCC mode and allow the per-vehicle 
data to be passed to the MIDAS controller without being modified.

The Click 516 utilizes the Click Supervisor software for user configuration. Communica-

tion between the Click 516 and Click Supervisor is easy to set up and use.

Physical Features

The Click 516 is based upon the Click 500 platform, so it has the same physical features as 

the Click 500. The physical features are used for easy installation and configuration.

Figure 2 – Diagram of the Click 516

Содержание Click 516

Страница 1: ...Click 516 USER GUIDE...

Страница 2: ...www wavetronix com 78 East 1700 South Provo Utah 84606 801 734 7200 Click 516 USER GUIDE...

Страница 3: ...CC rules which state that operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interf...

Страница 4: ...ent data messages and interval data from a SmartSensor HD Figure 1 The Click 516 The Click 516 operates in the following two states Normal and HIOCC These states are described below Normal State In no...

Страница 5: ...te There are only eight LEDs on the front of the Click 516 This means that only the first eight lanes will be monitored by the Click 516 front panel The LEDs will always come on starting with the firs...

Страница 6: ...hicle speed data to change the duration to greater than 1 9 seconds Once the Click 516 receives an interval where the speed is greater than the threshold the Click 516 will go out of HIOCC mode and al...

Страница 7: ...ule is used to forward data retrieved from the sensor and it is also used to configure the device with Click Supervisor The DB 9 port on the front of the Click 516 is the only port that is active when...

Страница 8: ...operation all DIP switches should be in the OFF position Warning The sixth switch of DIP switch 1 controls the mode of the device Make sure that this switch is in the OFF position If it gets turned o...

Страница 9: ...Click 516 Located on the front of the module below the DB 9 connector is a push button labeled Mode Switch The push button allows you to make selections from the menu see the Op erating Modes section...

Страница 10: ...complete properly Operating Modes The Click 516 has two operating modes Run mode and Device Setup mode These modes are accessed through the mode menu which is controlled via the push button the system...

Страница 11: ...ion The mode will now start running Run Mode blue solid Run mode is the first mode presented in the mode selection process but usually the second one to be used It might first be necessary at least th...

Страница 12: ...a SmartSensor HD and veri fies that the duration field of in the message is greater than 2 3 seconds If it is found to be shorter than 2 3 seconds the duration is change to be 2 3 seconds The Event D...

Страница 13: ...Click Supervisor using the Communication task from the main menu When detected the Click 516 will show up in the device list Highlight the device and press Select and after transferring the necessary...

Страница 14: ...elect the Setup Click task from the main menu and this will give the list of available drivers Select the Expert driver and click OK Figure 6 List of Drivers The driver will load the appropriate infor...

Страница 15: ...e Occupancy threshold that is used along with the Min Speed to determine if the Click 516 should enter HIOCC MODE The Speed of the interval must be below the Min Speed and the Occupancy of the interva...

Страница 16: ...sensor is storing Interval Data This field is read only Time Zone Allows you to select the appropriate time zone Table 3 Description of Sensor Tab Note If any of the read only fields are blank it mea...

Страница 17: ...t LED Solid Reset all settings except Serial Number and XML variable map Second LED Solid Reset all settings except Serial Number After being reset the Click 516 will return to the last mode that it w...

Страница 18: ...Euro Pat Nos 1435036 1438702 1611458 Other US and international patents pending Wavetronix SmartSensor Click Command and all associated logos are trademarks of Wavetronix LLC All other product or bra...

Страница 19: ...www wavetronix com...

Отзывы: