15
Fusion Sequence
Complete Fusion Process
Once Fuser is activated:
t"NCFSMJHIUPO'VTFSXJMMQVMTFPODFQFS
second as fusion takes place.
t"NCFSMJHIUPO$POUSPM6OJUXJMMQVMTF
once per second as fusion takes place.
t#V[[FSPO$POUSPM6OJUXJMMCFFQPODFQFS
second as fusion takes place.
t$POUSPM6OJUXJMMEJTQMBZi'VTJOHwBOE
count down time until fusion is complete.
When fusion is complete:
t"NCFSMJHIUPO'VTFSXJMMQVMTFSBQJEMZ
three times per second; this will repeat
three times for a total of nine pulses and
then return to solid “ready” status.
t"NCFSMJHIUPO$POUSPM6OJUXJMMQVMTF
rapidly three times per second; this will
repeat three times for a total of nine puls-
es and then return to solid “ready” status.
t#V[[FSPO$POUSPM6OJUXJMMCFFQSBQJEMZ
three times per second; this will repeat
three times for a total of nine beeps and
then return to quiet.
t$POUSPM6OJUEJTQMBZXJMMSFBEi'VTJOH
Complete!” alternating with “Connection is
Ready When Cool.”
Equipment Setup & Usage Instructions
Uncouple Fuser
t0QFO'VTFSKBXTCZMJGUJOHMFWFSUPOHVF
with thumb. Uncouple Fuser from Fitting.
t$IFDL'VTFST'VTF5FMJOEJDBUPS5IF
indicator button will protrude outward
after a successful fusion.
Fuse-Tel before fuse
Fuse-Tel after
successful fuse
Note: The “Warning! Reflective Error” warning will also appear if:
t5IFXSPOHTJ[F'VTFSJTVTFEXJUIB
Fitting.
t5IF'VTFSKBXTBSFOPUQMBDFEPSBMJHOFE
correctly on the Fitting's weld zone.
t5IF'VTFSKBXTBSFOPUDPNQMFUFMZDMPTFE
around the Fitting.
NOTICE
If fusion is interrupted or not
completed successfully:
t$POUSPM6OJUXJMMBVUPNBUJDBMMZBCPSUGVTJPO
process. The Control Unit display will read
“Warning! Reflective Error.”
t"NCFSMJHIUPO'VTFSBOE$POUSPM6OJUXJMM
flash until Fuser is uncoupled from the
Fitting.
t$POUSPM6OJUXJMMFNJUBOBMBSNVOUJMUIF
Fuser is uncoupled from the Fitting.
t*GGVTJPOTFRVFODFXBTBCPSUFEJONJE
sequence, let Fitting cool 15 minutes then
restart fusion process.
STEP 4
STEP 5