21
Completing A Fusion
(Cont.)
As the fusion proceeds, the following screen will be displayed:
This screen shows the number of the current fusion as well as the time remaining (In this case, 60
seconds). If you want to see more detailed information, press and hold the
UP button
to display the
following fusion information screen:
This screen displays the following information:
• The most recently measured voltage and current outputs of the processor.
• The total energy expended during this fusion, in amp-hours (In this case, 0.034 amp-hours).
This number increases during the fusion process as energy is expended.
• The present measured voltage of the generator (In this case, 118 volts).
• The current generator frequency. This number should remain relatively constant throughout the
fusion.
When the fusion is complete, if no errors were encountered during the fusion process, the following
screen will be displayed:
If errors were encountered during the fusion process, an
Error Code Message
will be displayed
(See page 33 for a list of possible Error Codes), and the following screen will be displayed after the
error message screen:
After the
Output Leads
are disconnected, the Rionfuser Electrofusion Processor will return to the
CONNECT LEADS
screen and will be ready to accept information for the next fusion.
FUSION NUMBER: 0125
60 sec
FUSION NUMBER: 0125
10 . 7v 8 . 2A
Energy: 0 . 034Ah
Gen: 118V 60 . 0Hz S
DISCONNECT
OUTPUT LEADS
FUSION COMPLETED
Successfully
DISCONNECT
OUTPUT LEADS
FUSION NOT COMPLETE
Errors Encountered