18
Power Up
(Cont.)
Manual Fusion
**Pre-configured CF or PVDF
fittings are always preferred and should be used whenever possible.
Manual Fusions require additional care and attentiveness on the part of the operator to ensure
the appropriate fusion parameters are entered. For this reason, Manual Fusions should ONLY be
performed by a fully trained operator using specifications provided by the fitting's manufacturer.
NOTE:
The Rionfuser Electrofusion Processor provides outputs for a complete fusion based on the
parameters manually entered by the operator. Remember to enter all parameters
EXACTLY
as
specified by the fitting manufacturer.
When beginning a Manual Fusion, the following screen will be displayed:
Enter the fusion current by using the
UP button
and
DOWN button
to increment and decrement
the value. As either button is held,the numbers will continue to scroll, slowly at first and then faster
as time passes. When the desired fusion current is displayed, press the
START button
to enter the
fusion time:
Enter the number of
MINUTES
to fuse using the
UP button
and
DOWN button
to increment and
decrement the current value. As either button is held, the numbers will continue to scroll, slowly at
first and then faster as time passes. When the desired number of minutes is displayed, press the
START button
to enter the seconds:
ENTER FUSION CURRENT
4.0 AMPS
ENTER FUSION TIME
0 min 30 sec