15
Power Up
(Cont.)
When the
Output Leads
are connected to the fitting, the processor will measure the fitting resis-
tance and display a screen similar to the following:
If you wish to view the resistance measurement made by the processor, press and hold the
UP
button
.
After the resistance measurement, you will be prompted to select the fitting style:
Use the UP/DOWN buttons to highlight the desired fitting style. Press the START button to select the
desired fitting style:
•
Rionfuse CF
allows the operator to automatically select between one of several fusion set
tings pre-programmed for a variety of CF fitting sizes.
•
Rionfuse PVDF
allows the operator to automatically select between one of several fusion
settings pre-programmed for a variety of PVDF fitting sizes.
•
Manual Fusion
allows the operator to manually configure the fusion current and the fusion
time.
Manual mode should only be used when it is not possible to use CF mode or PVDF
mode.
When using Manual Mode, the fitting manufacturer should be consulted to verify
proper fusion current and time.
Once the desired fitting style is selected, follow the instructions in the following sections that corre-
spond to the fitting style you chose.
VERIFYING
RESISTANCE
SELECT FITTING STYLE
1. Rionfuse CF
2. Rionfuse PVDF
3. Manual Fusion
Failure to verify that the fusion
information is correct before start-
ing a fusion could result in signifi-
cant damage to personal property,
personal injury, and/or death.
WARNING
!