1. Ensure the hot and cold supply lines have been flushed thoroughly to remove debris.
2. Once the lines are clear of debris, connect tap to water supply.
(For taps with flexible hoses: care must be taken to not twist or kink the flexible hose. If the isolation tap is
located in an awkward position or is too far, use another fitting and a flexible hose to extend the length and
to reduce the strain on the flexible hose)
3. Check again that all screws, nuts, grub screws and fittings have been fitted and tightened.
4. Check that all taps and the trigger spray are turned off.
5. Turn water supply on to check for leaks at all connection points.
The tap is now ready for use.
water connections
WARNING
Hot water will scald. Care must be taken to avoid scalding when using the trigger spray to deliver
hot water. Exposed metal sections of the mixer, riser assembly, hose connections and trigger
spray may become hot when in use and may cause burn injuries.
When not in use ensure all taps to the pre rinse assembly are turned off. The taps should not be
left on when unattended as this maintains pressure to the hose and trigger spray assembly, which
could result in water damage from flooding if in the unlikely event the hose or trigger spray were to
malfunction.