Param
No.
EDS Values
Read/Write
Default
Value
(EDS)
Parameter
Range
Comments
5
SetFailsafeEnable
Write
0
0-1
(False/True)
Enabled the failsafe speed.
If disabled the pump will
stop in the event of a
communications loss. If
enabled the pump will run
at the speed set in the
“SetFailsafeSpeed”
parameter
6
SetReverse
Write
0
0-1
(False/True)
If set the pump will run
anti-clockwise. Pump
defaults to clockwise
rotation
7
Run
Write
0
0-1
(False/True)
Set to 1 (true) to allow the
pump to run. 0 will stop
the pump. Note that
pump enable needs to be
set
8
RunEnable
Write
0
0-1
(False/True)
Need to set to 1 to allow
pump to run. Setting to 0
will stop the pump and
not allow the pump to
run.
9
ResetRunHours
Write
0
0-1
(False/True)
Resets the run hours
accumulator
10
PauseFlowTotaliser
Write
0
0-1
(False/True)
Set to 1 to pause the
internal FlowTotaliser
parameter. Setting to 0
will un-pause the
parameter
11
ResetFlowTotaliser
Write
0
0-1
(False/True)
Set to 1 to reset the flow
totaliser. Set to 0 to allow
the flow totaliser to
accumulate
102
m-630un-en-08
Содержание 630 U
Страница 21: ...1 2 m 630un en 08 21 ...
Страница 62: ...14 7 Network topology Star network Ring network 62 m 630un en 08 ...
Страница 126: ...23 5 Flow Sensor Reading The flow sensor value can be read via the Flow sensor reading screen 126 m 630un en 08 ...
Страница 128: ...Press SELECT to choose an option Press EXIT to return to the screen from where the MENU was called 128 m 630un en 08 ...
Страница 158: ...Press HOME to return and store the setting The input is now enabled in manual mode 158 m 630un en 08 ...
Страница 159: ...25 Help 25 1 Help Select Help from the main menu to access the help screens m 630un en 08 159 ...
Страница 179: ...Number Spare Description 8 TT0005 10mm 3 8in spanner 9 MRA3026A Track assembly m 630un en 08 179 ...