5.3 Disinfection of Dispense area

 

 

Disinfect after maintenance the dis- 
pense area with disinfection spray 
around to ensure perfect hygiene. 
Appoint a responsible person to 
carry out cleaning at least once a 
week, daily in hygiene sensitive 
environment.

 

Proceed here as follows:

 

 

•     Clean the entire dispense area with a 

disin- fectant.

 

•     Remove and clean the drip tray with 

disinfec- tant, make sure the drip tray is 
completely

 

dry before replacing it.

 

•     Spray the outlet nozzle outside and inside 

from beneath with disinfection spray. leave 
for 5 minute to soak.

 

•     Run 1 litre of water using the ambient 

water button to rinse the disinfectant from 
the nozzle.

 

•     Wait for approx. 30 minutes until the 

cooling the temperature of 4 °C - 8 °C 
reached.

 

•     Make sure that the responsible person on 

site is familiar with this cleaning procedure.

 

 

5.4 Ozone Generator - Active Sanitation

 

Ozone Sanitation - after every 
dispense a small quantity of 
O3 (Ozone) is injected into 
dispense valves, dispense 
pipes and nozzle. Ozone acts 
on and destroys bacteria. The

 

Ozone generator will activated every 30 minutes 
and after every dispense.

 

Examination:

 

Every 2 years the Ozone generator should be 
inspected to ensure its effectiveness (a simple 
test is to smell for the Ozone).

 

The equipment is built in a hygienically germ- 
free production facility. To ensure that the hygie- 
ne remains as intended make sure that cleaning 
instructions are adhered too. Use our pollution 
free and highly effective disinfection spray.

 

 

Cleaning and disinfection procedure:

 

1.  Clean the entire dispense area with 

a disinfectant.

 

2.  Remove the drip tray and empty.

 

3.  Clean the drip tray with disinfectant, rinse 

and dry before replacing.

 

4.   Spray the outlet nozzle outside and inside 

from beneath with disinfection spray. leave 
for 5 minute to soak.

 

5.  Run 1 litre of water into a jug using the ambi- 

ent water button to rinse the disinfectant from 
the nozzle.

 

6.  Clean the exterior of the equipment with a 

damp cloth. Before cleaning press the far 
right hand service button for 10 seconds the

 

will lock the other buttons to prevent acciden- 
tal dispense while cleaning. After cleaning, 
press the service button again for 10 seconds 
to enable the dispense buttons.

 

 
 

 

6

 

 
 
 
 

1

 

 

5.5 Hygiene guidance

 

Hygiene  guidance  and  hygiene  references  for 
the user. A careful HYGIENE is the basic con- 
dition for beverage quality and long life span of

 

the iQ3. A rigourous hygiene routine ensures a 

reliable, continuous use, a fresher drink supply

 

and a multitude of highly pleased users over the 

3

 

entire Life span of your water machine.

 

 

 

19

 

Содержание escowa Purus iQ3

Страница 1: ...Purus iQ3 Service Manual For the Installation Programming Cleaning and Maintenance...

Страница 2: ...enance It is a part of the equipment and must always be available close by the machine and always be available up to the disposal of the equipment If you should loss or damage the manual you must requ...

Страница 3: ...dge 17 5 1 1 Sanitation with the Service Cartridge 17 5 2 Sanitation 18 5 2 1 Sanitation with iQ sani clean SHOT using Anolyte 18 5 3 Disinfection of Dispense area 19 5 4 Ozone Generator Active Sanita...

Страница 4: ...Service Record Service Equipment IQ3 Nr Water Filter Inst Date Technician Date Counter Work Carried Out Technician 4...

Страница 5: ...1 Machine Construction Overview 1 1 Dismantling 3 1 1 Display and Buttons 2 Aerator with filter 2 3 Drip tray with capacity of 1 5 L 1 Chilled Still Water Sparkling Water Ambient Water Keypad Lock 3 5...

Страница 6: ...1 Machine Construction Overview 1 2 Inside front cover 1 2 1 4 2 3 1 Connection for external 4 3 CO2 bottle 2 Aerator change every 12 months 3 BRITA filter 4 Disposable CO2 bottle optional 6...

Страница 7: ...View from rear 1 5 4 2 3 7 6 3 1 2 1 External CO2 connection 5 4 2 Mains water inlet 3 Power supply connection 4 Programming button 5 Programming card slot 6 Machine identification plate 7 Evaporator...

Страница 8: ...1 Machine construction overview 1 4 removal of covers 1 1 2 1 Undo top cover screws 2 Remove top cover first 3 Remove side covers 3 3 3 8...

Страница 9: ...nal View 1 3 2 4 1 2 Left Side view 5 4 7 6 5 6 8 Right Side view 1 High pressure pump 2 Compressor Time out 4 h 3 Carbonator 4 PCB Cover 5 Ozone Generator 8 6 High pressure pump 7 Cooling fan 8 Inlet...

Страница 10: ...chine construction overview 1 6 view from top 1 Thermostat 2 Relief valve 7 5 bar 3 Level probes 4 Outlet valves 3 2 1 4 5 CO2 water 6 Chilled Still water 5 7 Ambient still water 6 8 Ozone injector 7...

Страница 11: ...allation setup and repair of the equip ment must only be carried out by a trained engineer The manufacturer is not responsible for damage to the equipment caused by Neglect to follow the guidelines in...

Страница 12: ...1 2005 A2 2007 Safety of the electrical household appliances and similar devices 2 4 Hazard Risk Please take into account local legal requirements with regards to installation and use of CO2 com press...

Страница 13: ...on 2 Chilled filtered water Selection 3 Chilled carbonated filtered water The temperature and the amount of carbonation of the water can be adjusted 3 3 Cleaning and Maintenance Before carrying out an...

Страница 14: ...following page 3 1 2 4 1 Connect the mains water supply to the iQ3 Do not turn 5 the water supply on Do not attach the mains cable 2 Remove the drip tray 3 Remove the front cover 4 Installation posit...

Страница 15: ...the bottle in the bracket at the front of the equipment Cut the hose to the required length and connect to the push fit connector at the front of the equipment Leave the CO2 regulator closed 3 Alterna...

Страница 16: ...er Open the mains water supply Check the water connection for leaks 3 Connect the equipment to the mains power supply 4 Press the Ambient water button and dispense 1 L of water to flush the filter The...

Страница 17: ...cartridge 4 Remove the filter Brita C1000 cartridge and replace with the Service Cartridge 4 5 Place a container under the discharge Press the key still chilled water button until the water turns blu...

Страница 18: ...Sparking water The pump will start and fill the carbonator 9 When the pump stops press button 1 sparkling water and dispense 500 ml of water turn the injector lever to water 10 Allow 30 minutes for th...

Страница 19: ...e its effectiveness a simple test is to smell for the Ozone The equipment is built in a hygienically germ free production facility To ensure that the hygie ne remains as intended make sure that cleani...

Страница 20: ...utton is pressed the display will light Enable Tones PT Tones ON ON or OFF ECO Reset KG PT CO2 saving counter Press T1 and T2 together to reset Power Ozone PT 00 Ozone generator Off 01 Ozone generator...

Страница 21: ...is absolutely necessary to ensure correct operation The filter must be replaced at its rated capacity Regular maintenance such as replacement of seals in use of CO2 systems and visual in spections sho...

Страница 22: ...spense nozzle Check the water and CO2 supplies are secure Clean the outside of the unit with a damp cloth to prevent accidental dispense press the right button 1 before cleaning for 5 seconds to lock...

Страница 23: ...em fan operate Dispense area Aerator disinfected or replaced as nesecary Dispense area cleaned and disinfected Drip tray Drip tray emptied cleaned and disinfected Overflow functionality of drip tray c...

Страница 24: ...e options Inlet water temperature Water outlet temperature Operating temperature room Temp Storage temperature Humidity 4 C 6 C 8 C 5 C to 25 C 4 C 6 C 8 C 10 C to 32 C 2 C to 35 C 35 75 Pressure rati...

Страница 25: ...s bacteria menti oned should not be in the water supply The filter will remove them if they are 10 3 CO2 connection There are two options for supplying CO2 to the equipment IQ3 CO2 disposable bottle s...

Страница 26: ...the bottle since there are different bottle forms Make sure the pressure regulating valve is closed and attach the to the bottle Fit the 8 mm hose on the lower con nection at the pressure regulating v...

Страница 27: ...not fitted correctly There is a leak in the system Check the water filter Turn OFF the water supply and call technician The Sparkling water dis pense is not sparkling CO2 Bottle is empty Replace CO2...

Страница 28: ...TTINGS RELEASE CO2 PRESSURE FROM THE CABORNATOR BY THE SAFETY VALVE 12 2 Wiring Diagram SONDA FRIGO CARBONATOR LEVEL Aux k CO2 Count 1 Switch Led F Boiler P COOL PROBE PROBES SONDE LIVELLO PRESSURE SE...

Страница 29: ...when applying for national safety certification of electrical products in the various member countries of IECEE Also it is now widely used among business partners in international trade for the detec...

Страница 30: ...ther industries organiza tions and associations We are a member of the Association AQUA ITALIA Water production plants for water intended for drinking purposes municipalities consor tia etc using the...

Страница 31: ...appliances Safety Part 1 General requirements EN 60335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 A13 2008 Safety of household and electrical applian ces Part 2 24 Particular requirements for refrigerat...

Страница 32: ...Notes 32...

Страница 33: ...Notes 33...

Страница 34: ...Notes 34...

Страница 35: ...Notes 35...

Страница 36: ...copyright engl version 2 09 12...

Отзывы: