5.3 Disinfection of Dispense area
Disinfect after maintenance the dis-
pense area with disinfection spray
around to ensure perfect hygiene.
Appoint a responsible person to
carry out cleaning at least once a
week, daily in hygiene sensitive
environment.
Proceed here as follows:
• Clean the entire dispense area with a
disin- fectant.
• Remove and clean the drip tray with
disinfec- tant, make sure the drip tray is
completely
dry before replacing it.
• Spray the outlet nozzle outside and inside
from beneath with disinfection spray. leave
for 5 minute to soak.
• Run 1 litre of water using the ambient
water button to rinse the disinfectant from
the nozzle.
• Wait for approx. 30 minutes until the
cooling the temperature of 4 °C - 8 °C
reached.
• Make sure that the responsible person on
site is familiar with this cleaning procedure.
5.4 Ozone Generator - Active Sanitation
Ozone Sanitation - after every
dispense a small quantity of
O3 (Ozone) is injected into
dispense valves, dispense
pipes and nozzle. Ozone acts
on and destroys bacteria. The
Ozone generator will activated every 30 minutes
and after every dispense.
Examination:
Every 2 years the Ozone generator should be
inspected to ensure its effectiveness (a simple
test is to smell for the Ozone).
The equipment is built in a hygienically germ-
free production facility. To ensure that the hygie-
ne remains as intended make sure that cleaning
instructions are adhered too. Use our pollution
free and highly effective disinfection spray.
Cleaning and disinfection procedure:
1. Clean the entire dispense area with
a disinfectant.
2. Remove the drip tray and empty.
3. Clean the drip tray with disinfectant, rinse
and dry before replacing.
4. Spray the outlet nozzle outside and inside
from beneath with disinfection spray. leave
for 5 minute to soak.
5. Run 1 litre of water into a jug using the ambi-
ent water button to rinse the disinfectant from
the nozzle.
6. Clean the exterior of the equipment with a
damp cloth. Before cleaning press the far
right hand service button for 10 seconds the
will lock the other buttons to prevent acciden-
tal dispense while cleaning. After cleaning,
press the service button again for 10 seconds
to enable the dispense buttons.
6
4
1
5.5 Hygiene guidance
Hygiene guidance and hygiene references for
the user. A careful HYGIENE is the basic con-
dition for beverage quality and long life span of
the iQ3. A rigourous hygiene routine ensures a
2
reliable, continuous use, a fresher drink supply
and a multitude of highly pleased users over the
3
entire Life span of your water machine.