background image

 

 

 

 

 

 

AN

T

 

1

 

S

P

3

5

4.

1

 

33

 

1

0

k

-2

5

°

 

2

 

1

 

12. Schematics

 

12.1 Water Circuit

 

Attention: do not bow the water tubes!

 

 

 

INLET 

SOLENOID

 

 

WATER 

  

 

INLET

 

 

 
 

VALVE

 

 
 

 

CARBON 

FILTER

 

 

 

PUMP

 

 

INLET 

SOLENOID

 

VALVE

 

WATER

 

 

CHECK 
VALVE

 

 

 

CARBON 

FILTER

 

 

PUMP

 

 
 

 

 

CARBONATOR 

LEVEL PROBE

 

OPTIONAL 

OZONE

 

GENERATOR

 

 

INTERNA L 

CHECK

 

6 BAR

 

MA X

 

 

 

CO2

 

BOTTLE

 

 

 

COLD 

PROBE

 

SAFETY 
VALVE

 

 

CHECK 

VALVE 
INDIDE

 

OPTIONAL 

OZONE

 

GENERATOR

 

 

TEMPERATED 
VALVE

 

 

COLD 
VALVE

 

CA RBONA TOR 

PLASTIC 
HEA D

 

 

LEVEL   PROBE

 

 

CO2

 

CA RBON DIOXIDE 

AREA

 

SPA RKLING 

WATER LEVEL

 

CA RTRIDGE 

VA LVE

 

TEMPERATED

 

VA LVE

 

COLD

 

VA LVE

 

SPA RKLING 

VA LVE

 

 

 

INJECTOR

 

 
 
 

 

6 BAR

 

 
 

 

NOZZLE

 

 

INTERNAL 

TWIN

 

CHECK 

CARTRIDGE

 

VALVE

 

 
 

H2O 

IN

 

 

 

CO2

 

IN

 

 

 
 

CARBONATOR

 

 

SPARKLING 
VALVE

 

REFRIGERATION 

CIRCUIT

 

 

WATER COOLING

 

SPIRA L 

  

 

 

CA RBONA TOR 

TANK

 

MA X

 

 
 

CO2

 

BOTTLE

 

 

NOZZLE

 

 

THERMA L 

INSULATION

 

AUTLET 

SPARKLING 

WATER

 

TUBE

 

 

WARNING!

 

BEFORE TO REMOVE THESE  FITTINGS

 

RELEASE CO2 PRESSURE FROM  THE CABORNATOR 

BY THE SAFETY VALVE

 

 

 
 
 
 
 

12.2 Wiring Diagram

 

 
 
 
 

SONDA  FRIGO

 

 

CA RBONATOR LEVEL

 

  

 

Aux k

 

CO2

 

Count 1

 

Switch    Led F.  Boiler P.

 

COOL PROBE

 

PROBES

 

SONDE LIVELLO

 

PRESSURE 

SENSOR

 

Pres S.           Light       Level         Aux      Cold P.

 

CA RBONATORE 

  

 

Fan

 

Count 2      Leak

 

 

Keyboard

 

CHIP CARD SLOT 

CONNECTOR

 

 

SMART CARD

 

 

 
 

 

DRIP TRAY PROBE 

SODE LIVELLO

 

RACCOGLIGOCCE

 

                    SET SWITCH

 

  

     ALARM LED

 

 

VENTOLA        FAN 12V DC

 

 

+

 

CN4

 

CN5

 

 

SW1  

SW2  

SW3 

SW4  

SW5  

SW6

 

SP 620.1

 

 

 

SP 621.1

 

+

 

 

N              N

 

 

Vac Line     BOILER

 

 

 

7        6      4  3  
5 1

 

 

N

 

 

L-UV

 

 

AG1

 

 

N  

N

 

 

PUMP     COMPRES

 

 

ELETTROVALVOLA

 

INGRESSO PRINCIPALE  230 V 50 HZ

 

EV4            MAIN INLET

 

SOLENOID VALVE

 

SPARKLING

 

SOLENOID VALVE

 

 

EMI FILTER 

L

 

FILTRO EMI

 

 

EV3

 

 

EV2

 

ELETTROVALVOLA 

ACQUA GASATA

 

CHILLED

 

SOLENOID VALVE 

ELETTROVALVOLA 

ACQUA FREDDA

 

230 V 50 HZ

 

 

 

230 V 50 HZ

 

 

TASTIERA TOUCH 

TOUCH KEYBOARD

 

 

 

SPINA ALIMENTAZIONE 

POWER SUPPLY IEC PLUG

 

GENERATORE OZONO 

OZONE GENERATOR

 

230 V 50 HZ

 

 

POMPA 

PUMP MOTOR

 

230 V 50 HZ

 

 

MOTORE 

FRIGO

 

COMPRESSOR 

MOTOR

 

230 V 50 HZ

 

 

EV1

 

NATURAL

 

SOLENOID VALVE 

ELETTROVALVOLA 
ACQUA NATURALE

 

 

230 V 50 HZ

 

 

 

28

 

Содержание escowa Purus iQ3

Страница 1: ...Purus iQ3 Service Manual For the Installation Programming Cleaning and Maintenance...

Страница 2: ...enance It is a part of the equipment and must always be available close by the machine and always be available up to the disposal of the equipment If you should loss or damage the manual you must requ...

Страница 3: ...dge 17 5 1 1 Sanitation with the Service Cartridge 17 5 2 Sanitation 18 5 2 1 Sanitation with iQ sani clean SHOT using Anolyte 18 5 3 Disinfection of Dispense area 19 5 4 Ozone Generator Active Sanita...

Страница 4: ...Service Record Service Equipment IQ3 Nr Water Filter Inst Date Technician Date Counter Work Carried Out Technician 4...

Страница 5: ...1 Machine Construction Overview 1 1 Dismantling 3 1 1 Display and Buttons 2 Aerator with filter 2 3 Drip tray with capacity of 1 5 L 1 Chilled Still Water Sparkling Water Ambient Water Keypad Lock 3 5...

Страница 6: ...1 Machine Construction Overview 1 2 Inside front cover 1 2 1 4 2 3 1 Connection for external 4 3 CO2 bottle 2 Aerator change every 12 months 3 BRITA filter 4 Disposable CO2 bottle optional 6...

Страница 7: ...View from rear 1 5 4 2 3 7 6 3 1 2 1 External CO2 connection 5 4 2 Mains water inlet 3 Power supply connection 4 Programming button 5 Programming card slot 6 Machine identification plate 7 Evaporator...

Страница 8: ...1 Machine construction overview 1 4 removal of covers 1 1 2 1 Undo top cover screws 2 Remove top cover first 3 Remove side covers 3 3 3 8...

Страница 9: ...nal View 1 3 2 4 1 2 Left Side view 5 4 7 6 5 6 8 Right Side view 1 High pressure pump 2 Compressor Time out 4 h 3 Carbonator 4 PCB Cover 5 Ozone Generator 8 6 High pressure pump 7 Cooling fan 8 Inlet...

Страница 10: ...chine construction overview 1 6 view from top 1 Thermostat 2 Relief valve 7 5 bar 3 Level probes 4 Outlet valves 3 2 1 4 5 CO2 water 6 Chilled Still water 5 7 Ambient still water 6 8 Ozone injector 7...

Страница 11: ...allation setup and repair of the equip ment must only be carried out by a trained engineer The manufacturer is not responsible for damage to the equipment caused by Neglect to follow the guidelines in...

Страница 12: ...1 2005 A2 2007 Safety of the electrical household appliances and similar devices 2 4 Hazard Risk Please take into account local legal requirements with regards to installation and use of CO2 com press...

Страница 13: ...on 2 Chilled filtered water Selection 3 Chilled carbonated filtered water The temperature and the amount of carbonation of the water can be adjusted 3 3 Cleaning and Maintenance Before carrying out an...

Страница 14: ...following page 3 1 2 4 1 Connect the mains water supply to the iQ3 Do not turn 5 the water supply on Do not attach the mains cable 2 Remove the drip tray 3 Remove the front cover 4 Installation posit...

Страница 15: ...the bottle in the bracket at the front of the equipment Cut the hose to the required length and connect to the push fit connector at the front of the equipment Leave the CO2 regulator closed 3 Alterna...

Страница 16: ...er Open the mains water supply Check the water connection for leaks 3 Connect the equipment to the mains power supply 4 Press the Ambient water button and dispense 1 L of water to flush the filter The...

Страница 17: ...cartridge 4 Remove the filter Brita C1000 cartridge and replace with the Service Cartridge 4 5 Place a container under the discharge Press the key still chilled water button until the water turns blu...

Страница 18: ...Sparking water The pump will start and fill the carbonator 9 When the pump stops press button 1 sparkling water and dispense 500 ml of water turn the injector lever to water 10 Allow 30 minutes for th...

Страница 19: ...e its effectiveness a simple test is to smell for the Ozone The equipment is built in a hygienically germ free production facility To ensure that the hygie ne remains as intended make sure that cleani...

Страница 20: ...utton is pressed the display will light Enable Tones PT Tones ON ON or OFF ECO Reset KG PT CO2 saving counter Press T1 and T2 together to reset Power Ozone PT 00 Ozone generator Off 01 Ozone generator...

Страница 21: ...is absolutely necessary to ensure correct operation The filter must be replaced at its rated capacity Regular maintenance such as replacement of seals in use of CO2 systems and visual in spections sho...

Страница 22: ...spense nozzle Check the water and CO2 supplies are secure Clean the outside of the unit with a damp cloth to prevent accidental dispense press the right button 1 before cleaning for 5 seconds to lock...

Страница 23: ...em fan operate Dispense area Aerator disinfected or replaced as nesecary Dispense area cleaned and disinfected Drip tray Drip tray emptied cleaned and disinfected Overflow functionality of drip tray c...

Страница 24: ...e options Inlet water temperature Water outlet temperature Operating temperature room Temp Storage temperature Humidity 4 C 6 C 8 C 5 C to 25 C 4 C 6 C 8 C 10 C to 32 C 2 C to 35 C 35 75 Pressure rati...

Страница 25: ...s bacteria menti oned should not be in the water supply The filter will remove them if they are 10 3 CO2 connection There are two options for supplying CO2 to the equipment IQ3 CO2 disposable bottle s...

Страница 26: ...the bottle since there are different bottle forms Make sure the pressure regulating valve is closed and attach the to the bottle Fit the 8 mm hose on the lower con nection at the pressure regulating v...

Страница 27: ...not fitted correctly There is a leak in the system Check the water filter Turn OFF the water supply and call technician The Sparkling water dis pense is not sparkling CO2 Bottle is empty Replace CO2...

Страница 28: ...TTINGS RELEASE CO2 PRESSURE FROM THE CABORNATOR BY THE SAFETY VALVE 12 2 Wiring Diagram SONDA FRIGO CARBONATOR LEVEL Aux k CO2 Count 1 Switch Led F Boiler P COOL PROBE PROBES SONDE LIVELLO PRESSURE SE...

Страница 29: ...when applying for national safety certification of electrical products in the various member countries of IECEE Also it is now widely used among business partners in international trade for the detec...

Страница 30: ...ther industries organiza tions and associations We are a member of the Association AQUA ITALIA Water production plants for water intended for drinking purposes municipalities consor tia etc using the...

Страница 31: ...appliances Safety Part 1 General requirements EN 60335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 A13 2008 Safety of household and electrical applian ces Part 2 24 Particular requirements for refrigerat...

Страница 32: ...Notes 32...

Страница 33: ...Notes 33...

Страница 34: ...Notes 34...

Страница 35: ...Notes 35...

Страница 36: ...copyright engl version 2 09 12...

Отзывы: