7. Intended Use
7.4 Information on Accessories
CO
2
- Please note following information:
• The CO
2
cylinder must be installed upright.
Cylinders must be secured with an additional
safeguard against falling over.
• The CO
2
cylinders must not be exposed to
direct sunlight. The bottles must be placed at
least two feet away from a heat source.
Important:
Please note the statutory regulations when
commissioning CO
2
.
8. Maintenance, cleaning and care
8.1 Cleaning Recommendation
The machine has left our production hygieni-
cally sanitised. For this condition to remain the
cleaning instructions given must be adhered
to. For disinfection use only an environmentally
friendly and highly effective disinfectant.
8.2 Weekly disinfection cleaning
• Clean the entire output area with disinfectant.
• Remove the drip tray and remove any
remai- ning water.
• After drying, wipe clean the drip tray with
dis- infectant and push the tray back into the
unit.
• Spray the dispense nozzle with
disinfectant spray.
• Rinse the nozzle after a soak time of 5
minutes with 1 liter of water to rinse off any
residue of the disinfectant from the inside of
dispense nozzle.
• Check the water and CO
2
supplies are
secure. Clean the outside of the unit with a
damp cloth.
• to prevent accidental dispense press the
right button
1
before cleaning for 5 seconds
to
lock the keypad. After cleaning, again press
the right button for 5 seconds to unlock the
keypad.
8.3 Sanitation
Sanitise the equipment during the routine
6 month service call. The device must only be
used with a water filter in operation. Read the
chapter about water filters, for more information
about consumption in liters. We recommend a
calibrated water meter be installed before on
the water supply to the machine to accurately
monitor the water usage.
8.4 Taste filter (water filter)
The Brita C1000AC filter fitted internally will
improve the taste of the water. Replace the
filter when stated capacity is reached or every
6 months.
Important:
Adverse effects can be seen if the filter is being
used past its capacity. This has adverse conse-
quences on the effectiveness of the device and
can be dangerous to your health. The device will
no longer filter out microbiological particles if it
has expired.
8.5 General information on maintenance
Ensure that: When cleaning and servicing the
power supply is removed. Do not use a steam
cleaner on the equipment.Cleaning must only be
carried out by a trained person.
1
22
Содержание escowa Purus iQ3
Страница 1: ...Purus iQ3 Service Manual For the Installation Programming Cleaning and Maintenance...
Страница 32: ...Notes 32...
Страница 33: ...Notes 33...
Страница 34: ...Notes 34...
Страница 35: ...Notes 35...
Страница 36: ...copyright engl version 2 09 12...