4.1.2 CO
2
Installation
Before installing the CO
2
the BRITA C1000AC must first be
fitted and flushed. See details on the following page.
Disposable or commercial CO
2
1
2
3
4
5
1. The equipment is supplied with a 4 mm CO
2
inlet hose. The
6
hose is suitable for the disposable CO
2
system. For more
details on CO
2
and valves please refer to later chapter.
2. Ensure that the pressure regulator valve is OFF (closed)
and connect the valve to the disposable CO
2
bottle, then
attach the 4 mm hose to the push fit on the valve. Mount the
bottle in the bracket at the front of the equipment. Cut the
hose to the required length and connect to the push fit
connector at the front of the equipment. Leave the CO
2
regulator closed.
3. Alternatively for commercial 6/10 kg CO
2
bottles, connect
link pipe to the push fit connector at the front. The external
CO
2
bottle is then connected at the 4 mm push fit
connector at the rear of the equipment.
4. Ensure that commercial bottle regulating valve is OFF (closed)
5. Fit the commercial bottle regulating valve as described in
the later chapter regarding CO
2
bottles and valves.
Leave the CO
2
regulator closed.
6. make sure the CO
2
bottle is secured and in a safe position.
Consider the CO
2
handling legal regulations.