32
warmhaus.com
Transparent Parameters Menu (TSP)
Designation :
All Warmhaus Wallhung Boilers
Object
Type-model(s)
Burner Control Transparent Parameter List
Parameter no.
Parameter
Value Field
MINERWA 25
Default
P15
Selection of boiler power
0 - 8
6
0 = 24 kw
1 = 28 kw
2 = 33 kw
3 = 50 kw
4 = 65 kw
5 = 24n kw - New Burner
6 = 24E kw ( D02 HEAT EXCHANGER )
7 = 28E kw ( D02 HEAT EXCHANGER )
8 = 33E kw ( D02 HEAT EXCHANGER )
P16
Combustion configuration - DO NOT CHANGE !
0 – 1
N/A
0 = Closed combustion chamber with combustion control
1 = Open combustion chamber with flue thermostat
P17
Climatic zone selection
1..81
34
P18
CH comfort selection;
0 - 2
0
0 = Eco ( if the Pre Heat will be used in the boiler Eco should be SET on the TsP. )
1 = Comfort ( if this adjusted on TsP, then Pre Heat Function is will not work )
2 = Disable
P19
Exhaust measurement configuration
0 -1
1
0 = Flue thermostad
1 = Flue NTC
P20
Minimum value for DHW setpoint ( C° )
35 C° - 50 C°
35
P21
Low temperature zone selection
0 -1
0
0 = Low temperature disabled
1 = Low temperature enabled / Max CH temperature 47°C
P22
Flues gas pipe length ( value 1 = 1 meter )
1 - 10
1
P23
Cycling time pump activation - cold zone ( value 1 = 1 minute )
1 - 10
0
P24
Push button child lock protection
0 -1
0
0 = Child lock disabled
1 = Child lock enabled
P25
Altitude loss compansation parameter ( value x 100 meters )
0 - 20
0
P26
Water hammer delay ( value 1 = 1 second )
0 - 3
0
P27
Pre Heat switch off temperature
30 - 75
55
P28
LCD back light activation time ( value 1 = 1 second )
0 - 120
45
P30
Ignition power
0 - 40
N/A
P31
Ignition fan speed ( P31 x 25 rpm )
80 - 160
128 = NG
128 = LPG
Содержание Minerwa 25 System IE
Страница 1: ...MinerWa 25 System IE CONDENSING SYSTEM BOILER INSTALLATION SERVICE MANUAL...
Страница 2: ...2 warmhaus com...
Страница 4: ......
Страница 26: ...26 warmhaus com 3 16 MINERWA 25 SYSTEM IE WIRING DIAGRAM WIRING DIAGRAM RISK OF ELECTRIC SHOCK...
Страница 57: ......