![WarmFlow WS18 Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/warmflow/ws18/ws18_instruction-manual_3560829026.webp)
26
3.5 Flue System
The appliance comes with an 80/100mm twin wall flue comprising a 1000mm long flue section
and a 600mm long flue terminal.
To assemble the flue supplied, insert the1000mm long flue section into the flue spigot on top of
the appliance. Secure with supplied selfdrilling screws. Place weatherproof collar over the joint
and apply a bead of silicone sealant around the collar prevent water ingress (refer to Figure 30).
This flue system is adequate only if the flue terminal is more than 2.3 meters from an adjacent
wall or surface as required by building regulations.
If the flue terminal is to be within 2.3 meters then please refer to Figure 31. Installations must
comply with the combustion appliance and fuel storage systems directive of regional building
regulations.
Figure 29: System Wiring Layout.
Apply
silicone
sealant to
prevent
water
ingress
Secure
flue with
selfdrilling
screws
Содержание WS18
Страница 4: ...6 APPLIANCE INSTALLATION COMMISSIONING CERTIFICATE REGISTRATION 33 7 APPLIANCE SERVICE RECORDS 35...
Страница 18: ...18 Engineer Figure 20 Flow Chart...
Страница 27: ...27 Figure 30 Flue Assembly...
Страница 28: ...28 4 COMMISSIONING AND SERVICING Figure 31 Flue Outlet Positions for Solid Fuel Appliances...
Страница 39: ...39 INTENTIONALLY LEFT BLANK...