Error messages
Subject to errors and modifications:
Error message
Possible cause
UDP port number invalid: use Port 42279
Duplicate assigned port number, port number greater than
65535 or text given instead of digits for port number
Checksum error: factory defaults were loaded
ROM error detected in configuration area
SNMP: IP address or name of Snmp manager not
entered
see Config >> Device >> Alarm >> Alarmx >> SNMP
UDP alarm: IP address or name of UDP server not
entered
see Config >> Device >> Alarm >> Alarmx >> UDP
UDP alarm: Port of UDP server not entered
see Config >> Device >> Alarm >> Alarmx >> UDP
Number of pulses exceeds 2000/sec: pulse mode input
x stopped!
Input signal frequency too high
50xxx-Mode: Invalid UPD IP address
see Config >> Device >> Mode 50xxx >> UDP Client
50xxx-Mode: Invalid TCP IP address
see Config >> Device >> Mode 50xxx >> TCP Client
Watchdog timer expired
Safety watchdog detected no network traffic within the
specified timeout time and the outputs were set to Safety
State
Box2Box: Invalid port number
Port number greater than 65535 or text entered instead of
digits for port number. Config >> Device >> Box 2 Box
Box2Box: Invalid slave IP address
No IP address specified or invalid address format. Config
>> Device >> Box 2 Box
Port number assigned more than once
Each mode must use a unique port number (see Appendix
7 Port Number List)
50xxx: Invalid local port number
Duplicate assigned port number, port number greater than
65535 or text entered instead of digits for port number.
Config >> Device >> Mode 50xxx
Box2Box: Invalid local port number
Duplicate assigned port number, port number greater than
65535 or text entered instead of digits for port number.
Config >> Device >> Mode Box2Box
Box2Box: Slave access denied, please check Box2Box
settings
Slave many be in Operator or Administrator Login, slave
working in 50xxx mode or is blocked by another mode.
Box2Box: Slave is in Box2Box Master Mode
see Config >> Device >> Box 2 Box for Slave Web-IO
Box2Box: Master could not be cleared, please log out
Slave is in Operator or Administrator Login and could not
clear the master connection data
Overload: Details under Diag>>Test>OutputConfig
An overload or no load was detected on one or more
outputs
Restart using Delete report
After a load error the corresponding output is enabled
again using Delete report.
After an error caused by high-frequency input signals,
pulse mode is activated again after Delete report.
Содержание 57630