W&T
Syslog
Subject to errors and modifications:
Diag Messages:
This option allows you to send error and diagnostic messages
to the Syslog server as a Syslog message with the priority
Deamon.Error
. As long as the Web-IO internal error memory is
not cleared, an error is sent only the first time it appears. Which
errors are currently in memory can be displayed using the Diag
page in the browser.
see: http://<IP address of Web-IO/diag
Enable:
At this point Syslog Enable must be selected in order to send
Syslsog system messages using the Web-IO.
Additional Syslog system messages can be sent using the
alarm functions of the Web-IO. Refer here to the section on
Alarms
.
Confirm your entries by clicking on the
Temporary Storage
button.
If you have no more configuration changes to make, you still
must activate the new settings. Use the
Logout
button or select
Config >> Session Control >> LogOut.
After clicking on the
Save
button all settings in the Web-IO are
updated and the start page is restructured in Default User
mode.