42
and the polarity change cable (2) to the PLUS connector. When welding with self-
shielding, gasless flux-cored wire, connect the ground wire to the PLUS
connector and the polarity change cable to the MINUS connector.
For TIG welding, the polarity change cable is disconnected and the TIG torch is
connected to the MINUS connector and the earth cable to PLUS connector.
In MMA welding, the polarity change cable is disconnected and the welding cable
and earth cable are attached according to the instructions on the label of the
electrode package:
(= +) Welding cable for PLUS connector
(= -) Welding cable for MINUS connector
(= ~) Polarity doesn't matter
Back panel
1. Main switch
In the OFF position, the machine is off, the machine is in the ON position. Make
sure that the machine's main switch is in the “OFF” position when connecting or
disconnecting the machine.
2.
Connect the
power cord
to a 230V 50Hz grounded outlet that is protected by
a minimum of 16 A slow blow fuse.
3.
The shielding gas hose supplied with the machine is connected to the
shielding gas connector
. The other end of the shielding gas hose is connected
to the pressure reducer connector of the shielding gas source.
The machine should be kept clean and dry. If rain cover is used, make sure
that the vents are not blocked.
1
2
3