- 9 -
Electrical connections
Safety instructions for wiring the heater:
Make sure that electrical cables are not damaged. Avoid: chafing, kinking, jamming or exposure to heat.
Electrical connections and ground connections must be free of corrosion and firmly connected.
Things to note about the connections
All connections must be arranged in the craft so that they can function perfectly under normal operating conditions.
Insulate unused cable ends.
The device uses 12 V (nominal) direct current voltage. To minimize current losses, make the power cable as short as
possible and avoid joining. The cross-sectional area of the cable is dependent on the length of the power cord. The
cross-sectional area of the cable must be consistent all the way from the stove to the battery. The maximum length of
the power cord is 10 m, based on 6 AWG cable.
The cross-sectional area of the cable
Total length of the power
cord (m)
Minimum cross-sectional area of the cable in square mm (US
Gauge)
0-4
4 (12 or 11 AWG)
4-6
6 (9 or 8 AWG)
6-10
10 (7 or 6 AWG)
If a thicker cable is required, make a separate joint in the power cord. See picture "Electrical connections of the device".
Electrical connections B
Electrical connections from power system:
12 V direct current system
Connect the red wire of the power cord to the plus terminal of the battery and the black or blue wire to the minus
terminal. A 15 A main fuse must be installed near the battery on the red plus wire of the power cord. See picture
above.
Содержание Spartan
Страница 1: ......
Страница 3: ......
Страница 9: ...7 Lift the heater into the installation plate And lock the device with the mounting bolts Measures...
Страница 10: ...8 Please note Mounting feet on earlier Spartan heaters were removed from production after Dec 31 2020...
Страница 36: ...35...