- 21 -
Solenoid valve
The solenoid valve 30012(available as accessory) prevents the tank from emptying in case the fuel line breaks. The
fuel filter should be installed before the solenoid valve.
Our recommendations in the following installation scenarios:
1. Fuel level is below the
heater/stove. Picture 1.
• Recommended installation scenario
• No special accessories required
2. Fuel level may temporarily rise
above the heater/stove (e.g. in the
fuel tank filler pipe or when the boat
tilts). Picture 2.
• No special accessories required but
solenoid valve 30012 is
recommended.
3. Fuel level is above the
heater/stove. Picture 3.
• Non-recommended installation
scenario
• Possible siphon problem
• Solenoid valve 30012 must be
installed in the fuel hose near the
tank.