- 23 -
Device operation
Ignition
The start-up process and heating is automatic.
The heater will ignite when the heaters starting icon is(3) selected and long pressed. A heating indicator text
”starting will, indicating that the heating is on.
A orange flame indicator light(1) will be lit when the burner flame has been ignited and the combustion has
stabilized
after about five minutes after the ignition. The whole process takes about 11 minutes.
First start-up
After installation or maintenance, if the fuel line is empty, the heater may not start at the first attempt. Start-up
phase with
an
empty fuel line is longer than normally and might take about 15 minutes. If the heater doens’t ignite
the orange combustion indicator light will not appear and panel gives error information. Turn off the heater. The
device cannot be restarted until the cooling phase is completed. When the cooling phase is finished, switch the
heater on again. If the device does not start after two attempts, it cannot be started again: the heater will lock itself
shows and shows lock icon. Find out the reason why the unit didn’t start and follow error solving instructions. After
locating the fault, release the locking (instructions in the maintenance section) and start-up the unit. Depending on
the length of the fuel hose, the heater may have to be started up several times during priming. Keep an eye on how
the fuel travels in the fuel hose while starting up the heater.
Adjusting the heat
Adjustment of temperature can be done by using thermostat mode (recommended use) or manual mode. The
desired mode is chosen by choosing thermostat- or to manual mode in control panel when unit is in off-mode. When
thermostat mode is chosen temperature, degrees is shown. In settings you can choose Celsius or Fahrenheit. In
manual mode there
are power levels
number from 1-6. Note! the heater will remember it’s last mode ie. if it is shut
down in thermostat mode next time when ignited it will start in the same mode ie. thermostat mode.
Thermostat mode:
Temperature is controlled by the thermostat (recommended use) The device starts when the heating switch (3) is
pressed in continuously for at least 2 seconds, after which the yellow power indicator light (9) lights to indicate that
the power is on. The orange combustion indicator light(1) will be lit, when the burner flame has been ignited and
combustion has stabilized. The starting phase will complete after about 11 minutes. After this phase, the heater will
run according to set power, adjustable by selecting temperature. After the heater has passed the ignition phase, you
can adjust the thermostat temperature by selecting desired temperature (2).
Pause mode:
The pause mode pauses the device automatically, if the temperature rises above the requested temperature, for
example, due to sunlight. The temperature must rise over +2 °C above the set value for ahalf an hour. If the device
has been paused, “pausing” text will appear to the screen. Pause-mode can be turned off by rising target
temperature. Heater will start automatically from pause mode when temperature has fallen over 2 degrees under
target level.
Manual use
The power can be adjusted manually. To enable this function select thermo-mode from main menu when heaters is
off. After the heater has been started up, the power can be adjusted smoothly by pressing right or left with buttons.
From manual mode to thermostat mode you can go by shutting down the unit, selecting thermostat mode, and by
starting unit.