- 36 -
Coolant temperature setting
Move the selection square to the
Target Coolant Temperature
and
press the
Select Button
.
Press
Arrow Buttons
(left or right)
to set the desired coolant
temperature.
Pause Mode
Coolant target temperature can be adjusted between 55 - 85 °C (131 F - 185 F).
The pause feature automatically turns the heater to pause if the coolant target temperature is exceeded by +10 °C (18
F). The unit will start heating again when the coolant temperature drops 10 °C (18 F) from the target temperature.
Heater will attempt to maintain the target coolant temperature.
Pausing will appear on the screen
when the heater is shutting down and
cooling. This takes several minutes.
If the heater is in Pause Mode,
Paused will appear on the screen.
Heater will re-start heating again
automatically.
Содержание Spartan
Страница 1: ......
Страница 11: ...9 Measures Viking water...
Страница 16: ...14 Installation example 1 Water coolant installation example Wallas on demand hot water accumulator...
Страница 17: ...15 Installation example 2 Water coolant installation example hot water tank calorifier...
Страница 64: ...9 Viking water mitat...
Страница 69: ...14 Esimerkkiasennus 1 Makeavesi l mm nsiirto j rjestelm n esimerkkiasennus Wallas puskuri l mminvesivaraaja...
Страница 70: ...15 Esimerkkiasennus 2 Makeavesi l mm nsiirto j rjestelm n esimerkkiasennus l mminvesivaraaja...
Страница 109: ......