- 32 -
Pause feature (Thermo Mode only)
Coolant target temperature can be adjusted between 55 - 85 °C (131 F - 185 F).
The pause feature automatically turns the heater to pause if the coolant target temperature is exceeded by +10 °C (18
F). The unit will start heating again when the coolant temperature drops 10 °C (18 F) from the target temperature.
Heater will attempt to maintain the target coolant temperature.
For example if the coolant temperature is set to 70 °C (158 F) then the heater will go to Pause mode when the
temperature rises to 81 °C (178 F). The unit will start heating again when the temperature drops to 59 °C (138 F).
If the heater is in Pause mode, "Paused" will appear on the screen. During pause, the fuel pump stops and the system
runs a normal cool down period and then goes silent. In summertime mode heater is started when hot water
accumulator temperature drops under the set target coolant temperature.
Summertime feature (hot water tank/calorifier)
Summertime feature can be selected (On/Off) from the Control Panel (settings).
When the summertime feature is not selected (Off) and there is a commercial hot water accumulator in the system, the
pause mode will be controlled by coolant target temperature as explained in the earlier chapter.
When the summertime feature is selected (On) and there is a commercial hot water accumulator in the system the
heater will go to pause mode when the coolant target temperature is exceeded by +10 °C (18 F) and it starts heating
when the hot water temperature drops below the target temperature.
Example:
Summertime
Target coolant temp.
Target hot water
temp.
Pause ON temp.
Pause OFF temp.
OFF
65 °C
50 °C
76 °C
54 °C
ON
65 °C
50 °C
76 °C
49 °C
Summertime feature (Wallas on-demand hot water accumulator)
Cylinderstat will be assembled to cold water inlet if the heater is wanted to be wake up when the hot water is used just a
little. Or to the hot water outlet if the water is wanted to be used fully. Hot water outlet will lessen the starts of the
heater, but is slower to react the needed hot water demand than the cold water inlet.
Shutdown
You can shutdown the heater any time by pressing the Select button down for more than 4 seconds. White color in the
Power on/off icon indicates that unit is shutting down.
Remote control
The heater can be controlled with IOS or Android WALLAS REMOTE APP in the local network or over the WLAN
network. Please read instructions from APP manual.
Содержание Spartan
Страница 1: ......
Страница 11: ...9 Measures Viking water...
Страница 16: ...14 Installation example 1 Water coolant installation example Wallas on demand hot water accumulator...
Страница 17: ...15 Installation example 2 Water coolant installation example hot water tank calorifier...
Страница 64: ...9 Viking water mitat...
Страница 69: ...14 Esimerkkiasennus 1 Makeavesi l mm nsiirto j rjestelm n esimerkkiasennus Wallas puskuri l mminvesivaraaja...
Страница 70: ...15 Esimerkkiasennus 2 Makeavesi l mm nsiirto j rjestelm n esimerkkiasennus l mminvesivaraaja...
Страница 109: ......