88
wallaceperimetersecurity.com
Phone: 866.300.1110
ELECTRICAL CIRCUITS
2. MOTOR BRAKES - MANDATORY
Each column motor has a 24VDC brake which must be disengaged to allow motor operation. The brake
is mechanically engaged and must have power to disengage.
Typical (example-only; see bolded text) motor brake connections to the post termination box are:
PRIMARY COLUMN MOTOR BRAKE:
Uses terminals (+) 25 & (-) 26
SECONDARY COLUMN MOTOR BRAKE:
Uses terminals (+) 27 & (-) 28
Always refer to site-specific drawings issued for the project you are working on for actual electrical
connections and installation methods.