SPEEDGATE Installation and Maintenance Manual
Revision 1 - MAY 2023
67
WIRE SIZES, TYPES AND LOCATIONS
Wire Sizes, Types and Locations
Table 5. Wire Gauge Sizes, Types and Locations applicable to PDTT and PDXT Models
Wire Gauge
Type
Between Columns 1 and 2*
14AWG
4C Secondary Motor Power, Shielded
18AWG
2C Secondary Motor Brake, Shielded
18AWG
2C Secondary Motor Disconnect, Shielded
24AWG
6C Twisted Pair Encoder, Shielded
18AWG
2C Through-beam Photo Eye Transmitter, Shielded
18AWG
4C Through-beam Photo Eye Receiver, Shielded
Conduit Between Gate and Operator Cabinet:
14AWG
4C Primary/Secondary Motor Power, Shielded (2pcs)
18AWG
12C Post Termination Box, Shielded
24AWG
6C Twisted Pair Encoder, Shielded (2pcs)
*Header Between Columns 1 and 2 for PDTT (TOP TRACK) Model; OR 2”
Underground Conduit Between Columns 1 and 2 for PDXT (TRACKLESS) Model.
Incoming Power: 208/230VAC Single Phase 20AMP
Wire leads from secondary column hardware are shipped bundled inside the secondary column.
PDTT (TOP TRACK) Model
PDXT (TRACKLESS) Model
The motor power cable runs through the header
and primary column into the conduit and
terminates into the operator enclosure.
The motor power cable runs through the primary
column into the conduit and terminates into the
operator enclosure.
The through-beam photo eye, motor brake
disconnect and the motor brake run through
the header into the Post Termination box for
termination.
The through-beam photo eye, motor brake
disconnect and the motor brake run to the Post
Termination box for termination.
Security access station needs to provide dry contacts for open (N.O.), close (N.O.), stop (N.C.)
commands.
Содержание SPEEDGATE
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 SPEEDGATE INSTALLATION...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 SPEEDGATE INSTALLATION...
Страница 59: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 1...
Страница 60: ......
Страница 61: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 2...
Страница 62: ......
Страница 63: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 3...
Страница 64: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 141: ......
Страница 142: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...