18
805.281.001
Date: March 22
rd
, 2017
MODE 4 – Not used, Motor stops
MODE 5 – Not used, Motor stops
MODE 6 – Not used, Motor stops
MODE 7 – Manual run up (no DMX needed) – Only for service and tests!
The rotator rotates clockwise (CW) with the speed set on the DMX-selectors. This function can
be used as a test-function.
E.g. Set the rotator to MODE 7 and the DMX address to 100, for a slow movement, or set the
DMX address to 500 for fast movement.
MODE 8 – Manual run up (no DMX needed) – Only for service and tests!
The rotator rotates counter clockwise (CCW) with the speed set on the DMX-selectors. This
function can be used as a test-function.
E.g. Set the rotator to MODE 8 and the DMX address to 100, for a slow movement, or set the
DMX address to 500 for fast movement.
MODE 9 – Not used, Motor stops
Table 2 - Overview of MODE functions
MODE
Function
Note
0
Not used, Motor stops
1
Slow speed change (Ramp)
2
Normal speed change (Ramp)
3
Fast speed change (Ramp)
4, 5, 6
Not used, Motor stops
7
Manual clockwise (CW) (no DMX needed)
Warning! Only for service and tests!
8
Manual counter clockwise (CCW) (no DMX needed) Warning! Only for service and tests!
9
Not used, Motor stops