background image

805.281.001 

 

Date: March 22

rd

, 2017

 

Introduction 

Before using the Wahlberg Rotator for the first time, please read this manual carefully. Failure in 
handling can cause injury of persons and/or damage the rotator. 
 
 

Package content 

1× 

Rotator 281 

3× 

Manfrotte Slim coupler 

3× 

Mounting bolts, nuts, and washers (M12) for slim coupler mounting 

1× 

PowerCON TRUE1 NAC3FX-W Female plug for power cable 

1× 

SpeakON SPX NL4FX Female plug for power/signal-throughput 

1× 

SpeakON SPX NL4FX Male plug for power/signal-throughput 

1x 

Instruction manual 

1x  

Clamp for shaft 

 

Description 

Rotator 281 is a rotator for stage use, mainly for use in theatres, shows and concerts. 
It  is  designed  for  rotating  lamps  and  other  electrical  devices.  The  rotator  has  a  positioning 
system  that  enables  a  Rotator  to  stop  at  any  desired  position.  The  load  is  up  to  150  kg.  The 
rotation speed is between 0.15 rpm and 6.8 rpm. 
 
The rotators are easily connected as a chain, allowing for advanced and creative ways of making 
dynamic movements.  The  rotator  is  controlled  by the  DMX  channels  from  the lighting  desk.  It 
has a built-in positioning system which is utilized in locating the desired position. The positioning 
system is controlled from a 16 bit DMX channel and is highly accurate; the rotator stops within 
1

°

. The speed of the rotator is likewise controlled from the lighting desk, and it is possible to set 

the left and right limits of the movement of the  rotator, adjusting its span of motion. Six DMX 
channels controls the wanted position and the speed of the movement, and the rotator finds the 
position  applied  on  the  lighting  desk.  The  movements  are  programmed  as  lighting  and  in 
interaction with the light.  
 
The control system ensures that the motor only is powered when: 

 

The control signal is reliable. 

 

The position and speed control is on. 

 

The motor position is calculated after witch a PID regulator calculates the motor speed 
and distance. 

 
Rotator 281 should only be operated by an experienced DMX-controlled-lighting-desk-operator.  
The lighting desk has to be programmed according to the manual, so the rotator will stop when 
the  speed  is  put  to  0  %.  It  is  also  possible  for  the  user  to  stop  the  rotator  on  the  main.  After 
power failure the start and 0

°

 position of the rotator needs to be reset before the rotator can 

function again.   
 
Manually operation of the rotator is only intended for mounting, service, and tests. 

Содержание 281

Страница 1: ...WWW WAHLBERG DK TELEPHONE 45 86 18 14 20 EMAIL sales wahlberg dk Rotator Item No 281 User Manual...

Страница 2: ...not when in use Always ground earth the rotator electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault pro...

Страница 3: ...to a fixed surface rig or structure when in use The rotator is not portable when installed Ensure that any supporting structure and or hardware can hold at least 10 times the weight of all the devices...

Страница 4: ...ropean Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure t...

Страница 5: ...PLUG 11 INSTALLING A POWER INPUT CONNECTOR ON A POWER CABLE 12 DATA LINK 14 TIPS FOR RELIABLE DATA TRANSMISSION 14 CONNECTING THE DATA LINK 14 ATTACHMENT POWER AND DATA LINK 14 POWER VOLTAGE 15 ATTACH...

Страница 6: ...ole XLR In link Rotating limit No limit Continuous rotation Rotating speed Variable 0 15 6 8 rpm Maximum attachment current 1 1 5 mm2 10A through power connection 1 1 5 mm2 10A through power connectio...

Страница 7: ...7 805 281 001 Date March 22 rd 2017 Rotator 281...

Страница 8: ...oning system which is utilized in locating the desired position The positioning system is controlled from a 16 bit DMX channel and is highly accurate the rotator stops within 1 The speed of the rotato...

Страница 9: ...indoors only Caution To reduce the risk of electric shock do not expose to rain store indoors Using for the first time Important The Rotator 281 must be protected from environmental factors such as p...

Страница 10: ...ator with full load it is important to use all 3 slim couplers when mounting To clamp a Rotator 281 to a truss 1 Check that the rigging clamp is undamaged and that the rigging structure can support at...

Страница 11: ...to the rotator Do not apply AC mains power to the rotator at any other voltage than that specified on the rotator s serial number label Power cables and power plug The Rotator 281 requires a power in...

Страница 12: ...281 001 Date March 22 rd 2017 Installing a power input connector on a power cable To install a Neutrik powerCON TRUE1 NAC3FX W input connector on a power Cable follow the original Neutrik instructions...

Страница 13: ...13 805 281 001 Date March 22 rd 2017...

Страница 14: ...ng runs 24 AWG cable is suitable for runs up to 100 meters 328 ft Never use a rotator s outputs to split a DMX link To split the link into branches use an opto isolated RS 485 splitter amplifier Termi...

Страница 15: ...y AC mains power to the rotators attachment power inlet at any other voltage than that specified on the rotators serial number label Attachment connection plug The Rotator 281 requires a power and dat...

Страница 16: ...16 805 281 001 Date March 22 rd 2017...

Страница 17: ...been disconnected Read the passage about controlling the clockwise CW end and counter clockwise CCW end positions to explore and setup the rotator best for your own particular need Warning Only opera...

Страница 18: ...Only for service and tests The rotator rotates counter clockwise CCW with the speed set on the DMX selectors This function can be used as a test function E g Set the rotator to MODE 8 and the DMX addr...

Страница 19: ...rough position DMX channel 1 The fine position and the rough position are multiplied in to a 16 bit channel The fine position is the LSB DMX channel 3 Speed This channel controls the speed of the rota...

Страница 20: ...tioning run To get the most precise run fit for your own needs it is possible to regulate the CW and CCW end positions This is done manually on DMX channel 4 and DMX channel 5 Reset example The DMX ch...

Страница 21: ...saving positions DMX channel 6 must be set between 50 and 55 DMX channel 4 moves the rotator in the CW direction and sets the 100 position Channel 5 moves the rotator in the CCW direction and sets the...

Страница 22: ...d the rotators will tend to follow that fade When fading the positions 1 The speed channel should be a set to 100 to gain the highest possible speed 2 The position channel should be added as a 16 bit...

Страница 23: ...are to be documented and kept available at the company The written result of the last inspection must be kept available at the site of operation e g by an inspection sticker on the rotator showing th...

Страница 24: ...epends heavily on operating conditions and environment so it is impossible to specify precisely whether and to what extent the performance will be affected The expected lifetime of the rotator depends...

Страница 25: ...CW Now the rotator will slowly turn clockwise Let the rotator run minimum one rotation must be done each time power is connected so the rotator identifies its angular zero position 12 Set channel 4 t...