background image

24 

805.281.001 

 

Date: March 22

rd

, 2017

 

 
On-site service  

On-site  service  and  maintenance  CAN  be  provided  by  the  Wahlberg  Motion  Design,  giving 
owners access to Wahlberg Motion Design’s expertise and product knowledge in a partnership 
that  will  ensure  the  highest  level  of  performance  throughout  the  product’s  lifetime.  Please 
contact Wahlberg Motion Design for details. 
 

Life time of the rotator 

It  is  Wahlberg  policy  to  apply  the  strictest  possible  calibration  procedures  and  use  the  best 
quality materials available to ensure optimum performance and the longest possible component 
lifetimes.  The  extent  of  wear  and  tear  depends  heavily  on  operating  conditions  and 
environment,  so  it  is  impossible  to  specify  precisely  whether  and  to  what  extent  the 
performance will be affected. The expected lifetime of the rotator depends on the load, travel 
length, mounted angle, as well as duty cycle. 

 

Spare parts 

Only parts ordered at or approved by Wahlberg should be used in the rotator to ensure product 
function and stability. Contact Wahlberg to inquire about spare parts. 

 
Power defect 

If the rotator does not react when the power is connected check the following: 

 

Check  that  the  power  plug  is  properly  connected,  both  to  the  POWER  IN  plug  on  the 
rotator and to the main power plug. 

 

Check that the fuse is tightly screwed on in the fuse cap, also if it has just been changed. 

 

Check that the fuse is intact. It can be replaced with a new 2.0A fuse. 
 

‘Power in’ 

Содержание 281

Страница 1: ...WWW WAHLBERG DK TELEPHONE 45 86 18 14 20 EMAIL sales wahlberg dk Rotator Item No 281 User Manual...

Страница 2: ...not when in use Always ground earth the rotator electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault pro...

Страница 3: ...to a fixed surface rig or structure when in use The rotator is not portable when installed Ensure that any supporting structure and or hardware can hold at least 10 times the weight of all the devices...

Страница 4: ...ropean Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure t...

Страница 5: ...PLUG 11 INSTALLING A POWER INPUT CONNECTOR ON A POWER CABLE 12 DATA LINK 14 TIPS FOR RELIABLE DATA TRANSMISSION 14 CONNECTING THE DATA LINK 14 ATTACHMENT POWER AND DATA LINK 14 POWER VOLTAGE 15 ATTACH...

Страница 6: ...ole XLR In link Rotating limit No limit Continuous rotation Rotating speed Variable 0 15 6 8 rpm Maximum attachment current 1 1 5 mm2 10A through power connection 1 1 5 mm2 10A through power connectio...

Страница 7: ...7 805 281 001 Date March 22 rd 2017 Rotator 281...

Страница 8: ...oning system which is utilized in locating the desired position The positioning system is controlled from a 16 bit DMX channel and is highly accurate the rotator stops within 1 The speed of the rotato...

Страница 9: ...indoors only Caution To reduce the risk of electric shock do not expose to rain store indoors Using for the first time Important The Rotator 281 must be protected from environmental factors such as p...

Страница 10: ...ator with full load it is important to use all 3 slim couplers when mounting To clamp a Rotator 281 to a truss 1 Check that the rigging clamp is undamaged and that the rigging structure can support at...

Страница 11: ...to the rotator Do not apply AC mains power to the rotator at any other voltage than that specified on the rotator s serial number label Power cables and power plug The Rotator 281 requires a power in...

Страница 12: ...281 001 Date March 22 rd 2017 Installing a power input connector on a power cable To install a Neutrik powerCON TRUE1 NAC3FX W input connector on a power Cable follow the original Neutrik instructions...

Страница 13: ...13 805 281 001 Date March 22 rd 2017...

Страница 14: ...ng runs 24 AWG cable is suitable for runs up to 100 meters 328 ft Never use a rotator s outputs to split a DMX link To split the link into branches use an opto isolated RS 485 splitter amplifier Termi...

Страница 15: ...y AC mains power to the rotators attachment power inlet at any other voltage than that specified on the rotators serial number label Attachment connection plug The Rotator 281 requires a power and dat...

Страница 16: ...16 805 281 001 Date March 22 rd 2017...

Страница 17: ...been disconnected Read the passage about controlling the clockwise CW end and counter clockwise CCW end positions to explore and setup the rotator best for your own particular need Warning Only opera...

Страница 18: ...Only for service and tests The rotator rotates counter clockwise CCW with the speed set on the DMX selectors This function can be used as a test function E g Set the rotator to MODE 8 and the DMX addr...

Страница 19: ...rough position DMX channel 1 The fine position and the rough position are multiplied in to a 16 bit channel The fine position is the LSB DMX channel 3 Speed This channel controls the speed of the rota...

Страница 20: ...tioning run To get the most precise run fit for your own needs it is possible to regulate the CW and CCW end positions This is done manually on DMX channel 4 and DMX channel 5 Reset example The DMX ch...

Страница 21: ...saving positions DMX channel 6 must be set between 50 and 55 DMX channel 4 moves the rotator in the CW direction and sets the 100 position Channel 5 moves the rotator in the CCW direction and sets the...

Страница 22: ...d the rotators will tend to follow that fade When fading the positions 1 The speed channel should be a set to 100 to gain the highest possible speed 2 The position channel should be added as a 16 bit...

Страница 23: ...are to be documented and kept available at the company The written result of the last inspection must be kept available at the site of operation e g by an inspection sticker on the rotator showing th...

Страница 24: ...epends heavily on operating conditions and environment so it is impossible to specify precisely whether and to what extent the performance will be affected The expected lifetime of the rotator depends...

Страница 25: ...CW Now the rotator will slowly turn clockwise Let the rotator run minimum one rotation must be done each time power is connected so the rotator identifies its angular zero position 12 Set channel 4 t...

Отзывы: