2 - 11
32DSKE02.B.1
INSTALLATION
SEPTEMEBER 2010
S/K-SERIES EXPORT USE SERVICE MANUAL
5.
INSTALLATION OF INTERLOCK DEVICE
An interlock device can be installed to prevent operation of the lift or vehicle when it is not safe to do so.
The inter-
lock supplied by the installing Ricon dealer is not a Ricon product.
If interlock option is installed, the S and K-Series lifts provides an electrical interlock signal to the vehicle that pre-
vents movement of the vehicle unless the platform is fully stowed. The interlock control also supplies power to the
lift only when the vehicle parking brake is set and the transmission is in PARK.
Some interlock devices lock vehicle transmission in PARK (or neutral) when lift is deployed, or do not allow lift to be
deployed unless vehicle transmission is in PARK (or neutral) and emergency brake is set. Other devices will stall
vehicle engine if lift is deployed and emergency brake is released or transmission is shifted from PARK (or neutral).
There may be other types of interlock devices that disable lift or vehicle to prevent unsafe lift operation.
Ricon is not aware of all available interlock products. For this reason it is very important that interlock products be
properly installed so that they do not interfere with safe operation or create any other hazards.
NOTE:
A 30 amp circuit breaker is located within the lift as a circuit protection device. The circuit interface used by
the installer must be capable of carrying an additional 30 amps of continuous current.
The installer must verify that none of the original equipment circuit breakers, fuses, or solenoids are bypassed, re-
moved, or altered. Be sure that no wires are left frayed or hanging loose after installation of an interlock device. If
you have any questions about proper installation of interlock devices, please contact our Product Support Depart-
ment.
WARNING
DO NOT OPERATE LIFT UNLESS YOU ARE CERTAIN THAT THE
INTEGRITY OF LIFT ELECTRICAL CIRCUITS HAS BEEN MAINTAINED.
CAUTION
Wiring attached directly to the positive battery terminal is not protected against short circuits
and must be kept to a length of 305mm (12 in.) or less. The wiring must be routed in a manner
that prevents pinching or abrasion by vehicle parts. The power source wire for the interlock cir-
cuit must be connected to a protected supply such as a dedicated accessory on an existing
fuse panel.