2 - 1
32DSKE02.B.1
INSTALLATION
SEPTEMEBER 2010
S/K-SERIES EXPORT USE SERVICE MANUAL
II. INSTALLATION
his chapter contains instructions for installing the RICON S-Series™ and K-Series™ Export Use wheelchair lift
into most private use vehicles, although custom installations are also possible in other types of vehicles. Due to
the wide range of lift applications, specific information for every possible application is not available. The follow-
ing general procedures will apply to most installations. Contact Ricon Product Support for instruction concerning instal-
lations not covered. To install lift, refer to following sections and perform procedures carefully and in the order that they
are presented. Be certain that installation instructions are followed exactly and do not eliminate any steps or modify
product.
NOTE:
Please review carefully the installation instructions (32ii427e) that are supplied with this lift before beginning the
following procedures. Where these procedures conflict, the installation instructions take precedence.
A. GENERAL
MECHANICAL
INSTALLATION
1. LIFT
LOCATION
The installation surface must be flat and level. It is recommended that lift be installed on a 13mm (1/2 in.), mini-
mum, high-grade plywood sub-floor. However, this additional installation height may not be acceptable in cases
where overhead clearance is limited.
Refer to Figure
2-1.
NOTE:
Check for proper travel clearance through doorway.
a. With doors fully open, place/position lift in vehicle doorway as close as possible to door, with lift's baseplate
assembly parallel to side of vehicle.
b. Allow a distance of 19mm (3/4 in.), if possible, between door and the part of lift closest to it. Adjust lift left
and right-side locations to accommodate subframe members.
c. Verify proper clearance of door frame, passenger seats, and outer edge of vehicle floor and possible inter-
ference with wires, fluid lines, subframe members, etc.
2. VEHICLE
STRUCTURAL
REQUIREMENTS
The following figures and text provide installation guidelines for the RICON S-Series and K-Series Export Use
wheelchair lift into most vehicles.
a.
VEHICLE DOOR OPENING DIMENSIONAL REQUIREMENTS
in millimeters and [inches].
MODEL
A
(Width)
B
(Height)
C
(Floor-To-Ground)
S1231
1029 [40.5]
1118 [44.0]
787 [31.0]
S2005
1080 [42.5]
1397 [55.0]
1067 [42.0]
S2030
1029 [40.5]
1397 [55.0]
1067 [42.0]
S2034
1029 [40.5]
1778 [70.0]
1067 [42.0]
K1200
1029 [40.5]
978 [38.5]
787 [31.0]
K2003
1029 [40.5]
1397 [55.0]
940 [37.0]
K2005
1080 [42.5]
1397 [55.0]
940 [37.0]
K2010
1130 [44.5]
1397 [55.0]
940 [37.0]
RSM0022501
A
B
C
VEHICLE FLOOR LEVEL
GROUND LEVEL
VEHICLE DOOR OPENING
FIGURE 2-1: DOOR OPENING REQUIREMENTS
T