2 - 10
INSTALLATION
SEPTEMBER 2010
32DSKE02.B.1
S/K-SERIES SERVICE MANUAL
b. Refer
to
Figure 2-13
. Ensure other wires that are fastened with the ground cable are secure and remain
connected after installation.
c.
12 VDC Systems
12 VDC powered lifts are chassis grounded and do not require a separate ground cable connection to bat-
tery. However, if the common side of the lift electrical system is connected to chassis with a cable, the ca-
ble must be attached in a manner that provides a reliable electrical connection. If ground cable is attached
to an existing ground circuit, the circuit must be capable of conducting an additional 100 amps.
d.
24 VDC Systems
1) Ricon recommends that a dedicated ground cable be used in 24 VDC installations. A 4GA cable, or
heavier, must be used.
2) Refer
to
Figure 2-10
. The ground cable is connected from the negative stud (-) on pump motor to the
negative battery terminal.
4. CONTROL
PENDANT
a. Refer
to
Figure 2-14
. Remove pump cover to gain access to chassis assembly then insert six-pin connec-
tor with cord through pump cover and chassis assembly openings.
b. Slide pump cover back onto pump assembly chassis.
RSM0018502
CORD
CONTROL PENDANT
SCREW
6 PIN CONNECTOR
PUMP COVER
PUMP CHASSIS
FIGURE 2-14: CONTROL PENDANT
c. Refer
to
Figure 2-14
. Install screw to secure control pendant bracket to pump assembly chassis.
CAUTION
Be sure that harness does not interfere with any moving
parts, or binds against any parts, or is pinched in any way.