background image

 

May 2, 2011

PRECAUTIONS

Static Discharge Precautions

10

Part Number 11694  Rev 1.6

JACE-700

 

MOUNTING AND WIRING GUIDE

|

Static Discharge Precautions

Static charges produce voltages high enough to damage electronic components. The 
microprocessors and associated circuitry within a JACE-700 controller are sensitive 
to static discharge. Follow these precautions when installing, servicing, or operating 
the system:

Caution

• Work in a static-free area. 

• Discharge any static electricity you may have accumulated. Discharge 

static electricity by touching a known, securely grounded object. Do not 
handle printed circuit boards (PCBs) without proper protection against 
static discharge. Use a wrist strap when handling PCBs.  The wrist strap 
clamp must be secured to earth ground.

Battery Precautions

Caution

• The NiMH battery used in this device may present a risk of fire or 

chemical burn if mistreated. Do not disassemble, heat above 122ºF 
(50ºC), or incinerate. Replace battery pack with type 
10SN-2/3AA60H-W-J1 (NPB-J700-BATT) only. Use of another battery 
may present a risk of fire or explosion.

• Dispose of used battery promptly. Keep away from children. Do not dis-

assemble and do not dispose of in fire.

• Replace external backup battery with Listed Power Source Battery Only.

WEEE (Waste of Electrical and Electronic Equipment) 

Recycling of Electronic Products: (International Installations)

In 2006 the European Union adopted regulations (WEEE) for the collection and 
recycling of all waste electrical and electronic equipment. It is no longer allowable to 
simply throw away such equipment. Instead, these products must enter the recycling 
process. To properly dispose of this product, please take it to a local recycling center.

If a local recycling center cannot be found, please return it to one of these offices:

Tridium Europe Ltd
1, The Grainstore
Brooks Green Road
Coolham, West Sussex
RH13 8GR United Kingdom

Tridium  Asia Pacific Pte Ltd
17 Changi Business Park Central 1
Honeywell Building
Singapore 486073

Tridium, Inc.
2256 Dabney Road, Suite C
Richmond, VA 23230

Содержание JACE-700

Страница 1: ...NG AND WIRING GUIDE The JACE 700 is a compact embedded controller server platform that allows integrated control and management of external devices over the Internet It provides support for two option...

Страница 2: ...medium or machine readable form without prior written consent from Tridium Inc Complete confidentiality trademark copyright and patent notifications can be found at http www tridium com galleries Sig...

Страница 3: ...Ethernet Ports 28 Maintaining the JACE 700 28 Cleaning 29 Required NiMH Battery Maintenance 29 Replacement Parts 31 Non replaceable Parts 31 Standard Replacement Parts 31 New Replacement Unit 31 Repl...

Страница 4: ...using the JACE 700 controller consult the following documents JACE NiagaraAX Install and Startup Guide IO 16 485 Mounting and Wiring Instructions NPB LON Option Install Sheet NPB 2X 485 Option Install...

Страница 5: ...e 2 show locations of important features of the controller Figure 1 JACE 700 Cover removed with 2 options installed on main board Typical installation requires an NPB PWR UN universal power supply mod...

Страница 6: ...itoring of UPS power and battery and an external enclosure door A rechargeable NiMH battery pack is included inside the unit and a separate connector provides recharging and monitoring of an external...

Страница 7: ...res universal AC input 90V 264V NPB PWR UN power supply module supplies 15Vdc 30VA Or a WPM XXX wall mount AC adapter can power the JACE 700 only requires removal of barrel plug end and wiring to end...

Страница 8: ...Defective Unit on page 33 Included in this Package Material and Tools Required Included in this Package Included in this package you should find the following items a JACE 700 controller These JACE 7...

Страница 9: ...results or might lose data Cautions contain an explanation of why the action is potentially problematic Warning Warnings alert the reader to proceed with extreme care in situations where there is a ch...

Страница 10: ...2 F 50 C or incinerate Replace battery pack with type 10SN 2 3AA60H W J1 NPB J700 BATT only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away fr...

Страница 11: ...range considering a 20 watt dissipation by the controller plus dissipation from any other devices installed in the same enclosure This is especially important if the controller is mounted inside an e...

Страница 12: ...g to hook DIN rail tabs over one edge of the DIN rail Figure 3 Step 3 Use a screwdriver to pry down the plastic locking clip and push down and in on the module to force the locking clip to snap over t...

Страница 13: ...oller is on a flat work surface you can leave the cable connected with the cover next to the unit See Figure 4 Figure 4 Removing JACE 700 controller cover Note If accessory modules are plugged into th...

Страница 14: ...Option Cards page 15 Remote I O modules To wire to the controller s right side 6 pin connector See About Remote I O Modules page 17 MiniPCI option card See About MiniPCI Cards page 18 PS OUT PS OUT B...

Страница 15: ...Port operates as LON1 if only one LON option or LON2 in slot 2 if two LON cards NPB 232 Single port RS 232 adapter with a DB 9M connector Supports baud rates up to 115200 30 pin option card If instal...

Страница 16: ...to install the option card under the tab Do not install an option card in Slot 2 with the card resting on top of the shield tab Otherwise an electrical short or some other issue from misaligned card...

Страница 17: ...vides both 15Vdc power and RS 485 communications to modules on that connected trunk and is located on the right side of the unit Each remote I O module has a DIN mount base and provides two 2 6 pin co...

Страница 18: ...ler in the following order 1 Install any option board LON RS 485 RS 232 etc in the available option slots See Installing an Option Card page 16 for a procedure For complete details refer to the specif...

Страница 19: ...he other LAN2 port For example isolating a driver s network traffic using LAN2 Do not use LAN2 as the primary port Serial There are two RS serial ports on the controller s base board Each has a UART c...

Страница 20: ...s and shield Wire in a continuous multidrop fashion to other RS 485 devices meaning minus to minus plus to plus and shield to shield Connect the shield to earth ground at one end only such as at the J...

Страница 21: ...r NPB PWR UN The NPB PWR UN module lets you power the controller and if installed connected I O modules from AC line power with a universal input range from 90 263Vac The NPB PWR UN module provides 15...

Страница 22: ...dule Make sure all modules in the mounted assembly are firmly connected together and secured Caution Do not energize the AC circuit wired to the NPB PWR UN until all other controller mounting and wiri...

Страница 23: ...leads then strip back 5 16 8mm of the insulation around each lead s conductor Terminate the two leads into the 6 position end connector plug as shown in Figure 9 bottom Before plugging connector into...

Страница 24: ...g to JACE 700 controller External 12V Backup Battery A 2 position connector provides support for an external 12V sealed lead acid SLA type rechargable battery For more details see About the Backup Bat...

Страница 25: ...he section About the Backup Batteries on page 26 Apply Power The JACE 700 controller does not include an on off switch To apply power you simply energize the AC circuit 90 263 Vac wired to the attache...

Страница 26: ...backup batteries NiMH battery pack A custom 10 cell NiMH nickel metal hydride battery pack is inside the controller mounted atop the shield and is secured by a metal bracket and two kep nuts This bat...

Страница 27: ...backup battery is performed as well as a periodic test A system alarm is generated if a battery test deems the backup battery to be bad Providing that the backup battery has tested good upon loss of p...

Страница 28: ...with the serial mode select jumper in the serial shell position see Figure 5 on page 14 This indicates that the DB 9 RS 232 port is operating in serial shell mode USB Three yellow LEDs LD1 LD2 and LD...

Страница 29: ...NiMH battery pack page 26 Therefore even a new unit or replacement battery will require up to 18 hours of powered operation before it can provide reliable backup power is at full charge The controller...

Страница 30: ...plug of the replacement battery into the NiMH battery connector on the main board of the controller The connector is keyed you cannot plug the battery in reversed Step 8 Replace the cover Step 9 Rest...

Страница 31: ...parts cannot be returned for credit and should be disposed of in an appropriate manner New Replacement Unit To replace an entire unit order and install a new JACE 700 controller If the faulty controll...

Страница 32: ...rnet serial LON modem and I O connectors from the con troller Note the position of installed option cards if any You must transfer them to the replacement JACE 700 controller Step 6 Remove the control...

Страница 33: ...btain a return materials authorization RMA number and other instructions Please provide Product model Serial number Nature of the defect PO number to secure the RMA United States Phone 804 254 7086 ex...

Страница 34: ...r own expense will be required to take whatever measures may be required to correct the interference Any unauthorized modification of this equipment may result in the revocation of the owner s authori...

Страница 35: ...America Manufacturer s Represen tative Steve Fey President Tridium Inc Product Model Numbers JACE 700 Type of Equipment Electrical Equipment for Measurement Control and Laboratory Use EMS Standards Ap...

Страница 36: ...ote Electronic and printed versions of this guide may not show the dimensions to scale Verify all measurements before drilling Figure 14 JACE 700 controller tab mounting dimensions Figure 15 JACE 700...

Отзывы: