3.3.  Ratings

A.  Voltage

          •   600 Volt Max. DC or Peak AC, use of wire M22759/11 

 

B.  Temperature

          •   -40°C to 125°C

3.4.  Performance and Test Description Product is designed to meet electrical, mechanical, and 

environmental requirements specified in Table 3 1. Unless otherwise specified, all tests should 

be performed at free air, room temperature, and ambient environmental conditions.

3.5.  Test Requirements and Procedures Summary 

Product Performance Specifications

Category

Test Description

Requirement

Procedure

Preliminary

Examination of Product

Meets requirements of product 

drawing

Visual, dimensional, and 

functional examination per 

applicable quality inspection 

plan

Electrical

Contact Resistance 

30 mΩ

EIA-364-06

Insulation Resistance

1000 MΩ minimum

EIA-364-21: Test between 

adjacent contacts assembled in 

housing at 500VDC

Dielectric Withstanding Voltage

1050 VDC test voltage at sea 

level

EIA-364-20: Test between 

adjacent contacts at 0.5 mA

Cross Talk

-30dB to 6.25 GHz

-40dB to 6.25 GHz

Cross talk between adjacent 

differential pair within the same 

insert

Cross talk between differential 

pair in adjacent inserts

Impedance

100Ω ±10Ω Per Differential Pair

Insertion Loss

-1dB to 6.25 GHz

Mechanical

Durability

See test sequence: Table 3-2

EIA-364-09: Mate and un-mate 

sample for 10,000 cycles

Retention Force: Receiver 

Contact

Contact shall not dislodge from 

module

EIA-364-29: Apply axial load of 5 

lbs to contact

Retention Force: ITA Contact

Insertion Force: Receiver 

Contact

Force to insert contacts into 

module ≤ 1.5 lbf

EIA-364-05

Insertion Force: ITA Contact

Mating Force

0.75 lbf Max per insert

EIA-364-13: Measure force 

necessary to mate samples at a 

normal rate of engagement of 

the ITA

Un-mating Force

≤ 1 lbf per insert

EIA-364-13: Measure force 

necessary to un-mate samples at 

a normal rate of disengagement 

of the ITA

1

Shall meet visual requirement, show no physical damage and shall meet requirement of additional tests as specified in Test 

Sequence in Table 3.2.

Table 3.1: Test requirements and procedure summary.

Содержание VTAC HSD

Страница 1: ...LE INSERT INSTALLATION REMOVAL INSTRUCTIONS SECTION 8 SMALL PCB AND RETENTION INSERT USAGE SECTION 9 VTAC HSD VERTICAL INSERT PART IDENTIFICATION SECTION 10 VTAC HSD VERTICAL INSERT PCB INSTALLATION I...

Страница 2: ...e upper left corner The front and rear of the VTAC HSD 90 Series receiver module are shown in Figure C The front has the position A1 notch The front side mates with the VTAC HSD 90 Series ITA module T...

Страница 3: ...ll be visible in the upper left corner The front and rear of the VTAC HSD 90 Series ITA Module are shown in Figure C The front mates with the VTAC HSD 90 Series Receiver Module The rear has the positi...

Страница 4: ...ying receptacle on the bottom When holding the i2 MX receiver the top can be determined when the letters and numbers are oriented as shown in Figure B The top position is designated by a black marking...

Страница 5: ...ha keying receptacle on the bottom When holding the i2 MX ITA the top can be determined when the letters and numbers are readable The top position is designated by a black marking around the upper slo...

Страница 6: ...t be extracted simultaneously to prevent damage to VTAC HSD Inserts NOTE The extraction tools are magnetic to aid in stacking them together 2 The indivdual patchcords can be identified by a blue inser...

Страница 7: ...insert will always be on top as shown in Section 2 1 Figure A VTAC HSD INSERT REMOVAL INSTRUCTIONS 1 Group the required number of extraction tools together for the given VTAC HSD patchcord shown in F...

Страница 8: ...l always be on top as shown in Section 2 1 Figure A VTAC HSD INSERT REMOVAL INSTRUCTIONS 1 Group the required number of extraction tools together for the given VTAC HSD patchcord shown in Figure B The...

Страница 9: ...be flush or below the module rear face as shown in Section 2 1 Figure C When plugging a stack of inserts the blue insert will always be on top as shown in Section 2 1 Figure A VTAC HSD INSERT REMOVAL...

Страница 10: ...e rear wiring side of the module shown in Figure A The VTAC HSD Insert s can only go into one side Once in place gently pull the wire to ensure the insert s is fully seated NOTE To be fully seated The...

Страница 11: ...d Screwdriver Flat Head Screwdriver 1 4 Nut Driver hollow shaft VTAC Extraction Tool Kit Receiver and ITA Part 910 112 130 REMOVAL INSTRUCTIONS 1 Disengage the ITA from the receiver 2 Using a flat hea...

Страница 12: ...10 130 XXX STRAIN RELIEF CLAMP NUT BACKSHELL SCREWS REMOVAL INSTRUCTIONS CONTINUED 4 Using a Phillips head screwdriver loosen the six screws captive that secure the backshell halves Remove the half wi...

Страница 13: ...G All inserts within each patchcord must be extracted simultaneously to prevent damage to VTAC HSD Inserts NOTE The extraction tools are magnetic to aid in stacking them together 2 While grasping the...

Страница 14: ...stall VTAC HSD Rail s orient rail s as shown in Figure A Figure C illustrates the identifiers to aid in orientation receiver rails shown The receiver rails are marked with RR receiver right and RL rec...

Страница 15: ...ystems in which the modules are oriented horizontally 2 Using a 3 32 Allen wrench tighten the top screw 1 to 2 full revolutions while pushing lightly against the face of the module 3 Maintain this pre...

Страница 16: ...UCTIONS 1 Using the Phillips head screwdriver fasten the strain relief to the rear wiring side of the VTAC HSD 90 Series Module with the 2 56 screws provided as shown in Figure A 2 Torque screws to 2...

Страница 17: ...Ended Insert is shown in Figure A The Rear Mating Side is shown in Figure B The Rear Mating Side mates with the VTAC HSD Right Angle Insert The Pin 1 position is shown in Figure C The VATC HSD Double...

Страница 18: ...nguishing features The top of the VTAC HSD Right Angle Insert is opposite the Compliant Pins shown in Figure A The Compliant Pins and PCB Mounting Surface mates with the PCB The Compliant Pins and PCB...

Страница 19: ...r orientation of the VTAC HSD Retention Insert Figure A as well as distinguishing features The top of the VTAC HSD Retention Insert Insert is opposite the PCB Mounting Surface shown in Figure A The Al...

Страница 20: ...art 910 112 132 INSERT INSTALLATION INSTRUCTIONS 1 Load the desired number of inserts into the tool The insert s should be loaded starting from the center of the tool and evenly distributed outward Th...

Страница 21: ...112 132 INSERT INSTALLATION INSTRUCTIONS 4 Push each insert to the rear of the tool Ensure that the rear of each insert is against the rear of the tool as shown in Figure D Make sure that the insert s...

Страница 22: ...d onto the contacts and hold the board in position as shown in Figure G 8 Place the other half of the tool on the top and hold the two halves together with the board in between them Make sure that the...

Страница 23: ...ide up as shown in Figure J 10 Using the press gentlely push the base and top of tool together until the contacts are seated Be careful not to over press 11 Remove the base the tool as shown in Figure...

Страница 24: ...shown in Figure A The VTAC HSD Double Ended Insert s can only go in one way 3 Engage Module with VTAC HSD Double Ended Insert s onto VTAC HSD Right Angle Insert s as shown in Figure B 4 Attach bracket...

Страница 25: ...own in Figure A The VTAC HSD Double Ended Insert s can only go in one way 3 Engage Module with VTAC HSD Double Ended Inserts onto VTAC HSD Right Angle Inserts as shown in Figure B 4 Attach the bracket...

Страница 26: ...rear wiring side of the module shown in Figure A Section 7 2 and Section 7 3 The VTAC HSD Double Ended Insert s can only go in one way 4 Insert VTAC HSD Right Angle Inserts into Module and VTAC HSD Do...

Страница 27: ...t is opposite the compliant pins as shown in Figure A The faces of the contact are symmetrical The first pin location can either be Pin 1 or Pin 8 Figure B The compliant pins are used to mount the ins...

Страница 28: ...its base Notice the alignment pins on either side of the base These alignment pins will be later used to locate the PCB and the base Figure B 3 Load the desired number of inserts into the base as sho...

Страница 29: ...ure C 8 Press the top insertion tool onto the base pushing the compliant pins of the insert into the PCB Do not over press Remove the PCB from the tool and verify the installation of each insert in th...

Страница 30: ...e parts of the system modules Receiver ITA and contacts ITA frame is not lined up when in the process of engagement with receiver This may indicate that the ITA is out of alignment or that a module is...

Страница 31: ...will be identified in section 2 2 Applicable Documents 2 1 Content The following documents form a part of this specification to the extent specified herein Unless other wise specified the latest edit...

Страница 32: ...ltage 1050 VDC test voltage at sea level EIA 364 20 Test between adjacent contacts at 0 5 mA Cross Talk 30dB to 6 25 GHz 40dB to 6 25 GHz Cross talk between adjacent differential pair within the same...

Страница 33: ...13 Cross Talk Between Pairs Same Insert 5 14 Dielectric Withstanding Voltage 5 11 Durability 8 15 7 Examination of Product 1 16 1 13 1 Insert Insertion Force 2 Insert Retention 3 Insertion Loss 3 12...

Страница 34: ...available visit vpc com Figure 2 Insertion loss SFP cables de embedded at 0 cycles and 10 000 cycles Figure 3 Return loss comparison between SFP cable only and SFP cable with terminated to VTAC inser...

Страница 35: ...ifferential pairs in two VTAC inserts at 0 cycles and 10 000 cycles The crosstalk between the two differential pairs within the SFP cable without VTAC is shown for reference Figure 6 Crosstalk between...

Страница 36: ...nal testing sequence as determined by development product and reliability quality engineering 4 3 Acceptance Acceptance is based on verification that product meets requirements of Table 3 1 Failures a...

Отзывы: