Operator Manual / 3. Getting started
29
3. Getting started
3.1 Checking the system
Before using the XR3D, verify the system is ready for operation by ensuring the following:
1. Perform a visual inspection for any obstruction in the tunnel or on the conveyor belt assembly. Check that
there is nothing under the belt or between the belt and the tunnel sides.
2. The XR3D power cord (2.5 m supplied with the XR3D) is connected to a grounded 110–120 VAC or 220–240 VAC
power outlet.
3. The emergency stop buttons are fully extended.
4. The circuit breaker is in the ON position.
5. The access panels are securely set in place with security screws. This ensures that the interlocking switches are
pressed.
6. The interlock switches on the doors must be engaged or the XR3D will not generate X-rays. The interlock
switches prevent the scanner from operating if the panels are open. A message appears on the monitor
indicating if the doors are open. The System & Operator Messages area on the operator screen does not display
any warning messages, for example
System Status: Locked
/
Interlock
or
Key Lock
as shown in
Figure 7
.
© VOTI 2020 / 900116-001
Содержание XR3D
Страница 8: ...Operator Manual 1 Introduction 8 Model Image XR3D 50 XR3D 60S VOTI 2020 900116 001...
Страница 9: ...Operator Manual 1 Introduction 9 Model Image XR3D 60 XR3D 6D VOTI 2020 900116 001...
Страница 10: ...Operator Manual 1 Introduction 10 Model Image XR3D 7 XR3D 7D VOTI 2020 900116 001...
Страница 11: ...Operator Manual 1 Introduction 11 Model Image XR3D 100 XR3D 100D VOTI 2020 900116 001...
Страница 12: ...Operator Manual 1 Introduction 12 Model Image XR3D 100B XR3D 100BD VOTI 2020 900116 001...
Страница 13: ...Operator Manual 1 Introduction 13 Model Image XR3D 15D XR3D 18D VOTI 2020 900116 001...
Страница 60: ...Operator Manual 5 Conducting a scan 60 Figure 51 Switching X Ray Views on Screen 2 VOTI 2020 900116 001...
Страница 96: ...Operator Manual 6 Administration module 96 Figure 91 Admin Menu Software Versions VOTI 2020 900116 001...
Страница 99: ...Operator Manual 7 TIP management 99 Figure 94 BioSans Login Menu Log in to TMS VOTI 2020 900116 001...
Страница 116: ...Accident Investigation Report Appendix...
Страница 118: ...VOTIDETECTION COM VOTI Detection 790 Begin St St Laurent QC H4M 2N5 Canada...