Flooded Engine
EVC Engines
21181
51264a
51260b
To clear a flooded engine:
1.
Turn the key to ON
I
(RUN).
2.
On the EVC control panel, press and hold the
NEUTRAL BUTTON
3
while moving the control
lever
2
forward to the shift position
F
.
3.
Let go of the NEUTRAL BUTTON and move the
remote control lever to FULL THROTTLE
T
.
4.
Turn the ignition switch to START
II
. If the engine
does not start, then try again.
NOTICE!
After a second attempt, if the engine
still does not start, return the control lever to the
neutral position and try a normal engine start.
5.
As soon as the engine starts:
● Return the handle to IDLE (NEUTRAL
N
).
● Return the key to ON or RUN
I
.
NOTICE!
Immediately after engine start-up, look at all
instruments. If any readings are abnormal, stop the
engine and determine the cause.
Starting
47700387 06-2009