Power Relay
Symptom:
Faulty ignition relay.
EVC Action:
Engine will stop. If engine is off, engine will not
start.
Operator Action:
AMBER
–
● Check ignition relay in fuse box and replace if neces-
sary.
● Contact a Volvo Penta dealer if the fault persists.
Power Trim Faults
Symptom:
Fault in power trim system. Possibility that the
system does not detect relays or trim sensor drifts without
operator action. Also may be a trim sensor fault resulting in
no readings.
EVC Action:
Power trim assist function is turned off. Normal
trimming may be disabled in some situations.
Operator Action:
RED
● If normal trimming does not function, use emergency
trimming procedure. For additional information, please
see
Emergency Trimming
.
● Contact a Volvo Penta dealer.
AMBER
–
Start Relay
Symptom:
Faulty relay.
EVC Action:
None while engine is operating. If engine is off,
engine will not start.
Operator Action:
AMBER
–
● Check start relay in fuse box and replace if necessary.
● Contact a Volvo Penta dealer if the fault persists.
Fault Code Register
110
47700387 06-2009
Содержание 21182210
Страница 1: ...OPERATOR S MANUAL 3 0L 5 0L 5 7L 8 1L SX A DPS A ...
Страница 95: ...51318 51319 51320 Operation 47700387 06 2009 93 ...
Страница 181: ...22775 The tune up and color code decal is located on the engine cover Technical Data 47700387 06 2009 179 ...
Страница 188: ......