38
b) Lab Mains Adapter VLP-2602 OVP (Item no. 513865)
Operating voltage ............................... 230 V/AC, 50 Hz ( ±10%)
Power consumption ............................ 450 VA max.
Output voltage A ................................. 0 - 60 V/DC (-200 mV ~ 61.5 V/DC)
Output voltage B ................................. 0 - 60 V/DC (-200 mV ~ 61.5 V/DC)
Output voltage C ................................. 3 - 6 V/DC
Output current A ................................. 0.01 - 2 A controllable
Output current B ................................. 0.01 - 2 A controllable
Output current C ................................. 2 A (max.)
Residual ripple ....................................
≤
2 mV rms (rms = effective)
Stability ................................................ < 9 mV/h
Reaction differentials .......................... load change 0 ~100 %
≤
15 mV /
≤
10 mA
grid fluctuations ±10%
≤
25 mV /
≤
15 mA
Main fuse (5 x 20 mm) ........................ T3.15 A / 250 V (slow trigger characteristics)
Dimensions (W x H x D) ..................... 435 x 110 x 245 mm
Weight ................................................. 11 kg
Operating temperature ....................... +5 °C to +40 °C
Ambient air humidity ........................... max. 85% rel. humidity ( non-condensing)
Protection class .................................. I
c) Lab Mains Adapter VLP-1303 OVP (Item no. 513861)
Operating voltage ............................... 230 V/AC, 50 Hz ( ±10%)
Power consumption ............................ 210 VA max.
Output voltage A ................................. 0 - 30 V/DC (-200 mV ~ 31.5 V/DC)
Output voltage B ................................. 3 - 6 V/DC
Output current A ................................. 0.01 - 3 A controllable
Output current B ................................. 2 A (max.)
Residual ripple ....................................
≤
2 mV rms (rms = effective)
Stability ................................................ < 5 mV/h
Reaction differentials .......................... load change 0 ~100 %
≤
15 mV /
≤
6 mA
grid fluctuations ±10%
≤
4 mV /
≤
5 mA
Main fuse (5 x 20 mm) ........................ T1 A / 250 V (slow trigger characteristics)
Dimensions (W x H x D) ..................... 255 x 100 x 245 mm
Weight ................................................. 4.6 kg
Operating temperature ....................... +5 °C to +40 °C
Ambient air humidity ........................... max. 85% rel. humidity (non-condensing)
Protection class .................................. I