l) Temperature Measurement with Contact Sensor
Contact measurement is only permissible with powered-down objects. Danger of elec-
tric shock!
Due to its build, the included wire sensor is only designed for a measuring range
between -20 and +230 °C. With optional K-type thermal sensors, the complete meas-
uring range of the DMM can be used.
Proceed as follows for the measurement:
• Switch on the DMM and select the measuring
range according to desired resolution: “1 °C” or
“0.1 C”.
• Connect the K-type measuring adapter to the “V”
(+) and “COM” (-) in the correct polarity.
• Connect the sensor to the measuring adapter in
the correct polarity. The polarity is marked on the
plug.
• Guide the measuring prod to the object to be
measured. The measured value is shown in the
main display in °C.
• Switch off DMM after measuring.
The measured temperature must only be applied to the measuring prod. The measu-
ring device must be in the specified environment to prevent measuring errors.
68