c) Opening Meter
The connected lines must be disconnected from the measuring device and all measu-
ring objects before the device is opened. Switch off the DMM.
Proceed as follows to open it:
• Disconnect all measuring leads from the meter and switch it off.
• Unscrew and remove the two rear battery compartment screws (18).
• Pull the battery cover (18) from the measuring device at a 90° angle.
• This battery compartment is now accessible.
• Remove the mounting bracket ad remove all six housing screws.
• Draw the housing apart parallel. Make sure that it does not catch.
• The fuses can be accessed now.
• Close the housing again in the reverse order and screw the battery and fuse compartment
closed.
• The meter is ready for use once again.
75